background image

CAUTION ATTENTION: 

PRECAUCION: 

RISK OF ELECTRIC SHOCK 

DO NOT OPEN 

RISQUE DE CHOC ELECTRIQUE 

N’OUVRIR PAS 

RIESGO DE ELECTROCHOQUE 

NO ABRIR LA TAPA 

CAUTION: TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT REMOVE 

COVER (OR BACK). NO USER-

SERVICABLE PARTS INSIDE. REFER 

SERVICING TO QUALIFIED SERVICE 

PERSONNEL

AFIN DEVITER UN CHOC ELECTRIQUE ET 

LES CONSEQUENCES GRAVES QUI 

POURRAIENT ENRESULTER, TENTEZ 

PAS D’OUVRIR L’APPAREIL ET DE 

TOUCHER AUX COMPOSANTS 

INTERNES SANS LA PRESENCE D’UNE 

PERSONNE QUALIFIEE.

PARA REDUCIREL RIESGO DE 

SACUDIDAS ELECTRICAS, NO DEBERA 

QUITARSE LA TAPA (NI PARTE 

POSTERIOR). CONSULTESE AL 

PERSONAL CAPACITADO PARA LAS 

REPARACIONES INTERNAS

WARNING:

 TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. 

ADVERTENICIA: 

PARA EVITAR EL RIESGO DE INCENDIO O SACUDIDA ELECTRICA, NO DEBERA EXPONERSE ESTE 

APARATO A LA LLUVIA O HUMEDAD. 

CAUTION:

 TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION CORD, RECEPTACLE OR 

OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.

ATTENTION:

 POUR PREVENIR LES CHOCS ELECTRIQUES NE PAS UTILISER CETTE FICHE POLARISEE AVEC UN 

PROLONGATEUR. UNE PRISE DE COURANT OU UNE AUTRE SORTIE DE COURANT, SAUF SILES LAMES PEUVENT 
ETRE INSEREES A FOND SANS EN LAISSER AUCUNE PARTIE FOND SANS EN LAISSERAUCUNE PARTIE A DECOUVERT.

PRECAUCION:

 PARA EVITAR SACUDIDAS ELECTRICAS, NO DEBERA UTILIZARSE ESTA CLAVIJA POLARIZADA CON UN 

CORDON DE PROLONGACION, RECEPTACULO U OTRO TIPO DE SALIDA A MENOS QUE SE HAYAN INSERTASO 
COMPLETAMENTE LAS LENGÜETAS PARA EVITAR SU EXPOSICION.

NOTE: 

Some products are equipped with dual or multi-voltage transformers (which is indicated on the back panel). If you wish to 

change the voltage, please bring your unit to an authorized service technician for internal conversion.

ATTENTION: 

Quelques piéces sont munies de transformateurs á double ou á multi-voltage (indiqué au panneau arriére). Si vous 

voulez changer le voltage, veuillez apporter votre appareil au fournisseur de pour le transformer.

ZUR BEACHTUNG: 

Einige Geräte sind mit Umschaltern für unterschiedliche Netzspannungen ausgerüstet (ein Vermerk auf der 

Rückseite weist darauf hin). Die Anpassung, wenn notwendig, muß von einem qualifizieren Techniker in einer Servicestation 
vorgenommen werden.

NOTA: 

Ciertos componentes de están dotados de transformadores de doble tensión o de varias tensiones (Io que se indica en el 

panel posterior). Si se desea cambiar la tensión, sírvanse llevar el aparato a un técnico autorizado por para su conversión interna.

NOTE TO CATV SYSTEMS INSTALLER:

 This reminder is provided to call the CATV system installer’s attention to Article 820-22 of 

the NEC that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the 
grounding system of the building, as close to the point of cable entry as practical.

NOTA PARA EL INSTALADOR DE ANTENAS DE TELEVISION COLECTIVAS:

 La presente advertencia se provee para llamar la 

atención del instalador al Artículo 820-22 de NEC (Córdigo Eléctrico Nacional) donde se facilitan las directrices para la pertinente 
puesta a tierra y que especifica en particular que el condutor a tierra del cable debe connectarse al sistema de conexión a tierra 
del edificio, lo más proximo posible al punto de entrada del cable.

The lightning flash with arrowhead, within an equilateral 
triangle, is intended to alert the user of the presence of 
uninsulated “dangerous voltage” within the product’s 
enclosure; that may be of sufficient magnitude to constitute a 
risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended 
to alert the user of the presence of important operating and 
maintenance (servicing) instructions in the literature 
accompanying the appliance.

Warning:

 This speaker shall not be placed in a closed area during operation so that the main switch can be easily accessed by 

the user.

Summary of Contents for DSM1

Page 1: ...M Audio Studiophile DSM1 Active Studio Monitors English User Guide...

Page 2: ...eurs double ou multi voltage indiqu au panneau arri re Si vous voulez changer le voltage veuillez apporter votre appareil au fournisseur de pour le transformer ZUR BEACHTUNG Einige Ger te sind mit Ums...

Page 3: ...he appliance should be cleaned only with dry cloth 11 POWER SOURCES The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the app...

Page 4: ......

Page 5: ...ctors and Controls 3 Front Panel 6 Chapter 3 Setup and Operation 7 Getting Started 7 Setting Up the Speakers 7 Configuring and Connecting AC Power 9 Power Up and Power Down 10 Connecting Audio 10 Conf...

Page 6: ...M Audio Studiophile DSM1 Guide vi...

Page 7: ...olation pads M Audio Registration Information Card Features DSM1 speakers have the following features Self powered bi amplified operation Selectable analog and digital inputs Custom tuned enclosures A...

Page 8: ...curate frequency re sponse and stereo imaging Bass Reflex Port A dual flange bass reflex port provides enhanced low frequency response and clarity while minimizing extraneous noise and vibration Drive...

Page 9: ...Back Panel Connectors and Controls Figure 1 Back panel of the DSM1 Analog Input XLR Analog Input TRS Analog Input Sensitivity Digital Input S PDIF Digital Thru S PDIF Digital Input AES EBU Bass Reflex...

Page 10: ...le when the digital source is powered off When the clock signal is restored the speaker wakes up from standby mode Analog Inputs The DSM1 speaker provides an XLR analog in put connector and a balanced...

Page 11: ...in the digital domain Trim values range from 22 dB to 10 dB EQ Settings The DSM1 speaker has a series of 12 switches for setting the following EQ controls High Frequency Shelf Sets an adjustable high...

Page 12: ...e front of the DSM1 speaker indicates the following states Front panel of the DSM1 Front Panel LED States LED State Indication Blue Analog Input Digital Input Lock Yellow Digital Input No Lock Blue fl...

Page 13: ...e back of each speaker Reusing the Speaker Packaging Retain your packaging for future use The car tons are durable and reusable and can be used to safely transport your speakers Setting Up the Speaker...

Page 14: ...rs are ap proximately the same height as your ears in the mixing position Place speaker pairs the same distance from the two sides of the room Place speakers so that the backs of the speak ers are a m...

Page 15: ...use 1 Turn off power to the speaker and disconnect the AC power cord 2 Use a small screwdriver to remove the fuse holder 3 Remove the currently installed fuse 4 Install the new fuse in the fuse holder...

Page 16: ...mute or power off your speaker system first before powering off other devices in your studio Connecting Audio This section explains how to make analog and digital audio connections to DSM1 speakers C...

Page 17: ...are us ing a digital source you can connect it to either the AES Digital In or the S PDIF In of one of the DSM1 speakers It does not matter which speaker is connected to the source The Digital Thru S...

Page 18: ...Configuring Speaker Settings Volume Trim Settings The Volume Trim control lets you match the in put sensitivity of speaker to the source If you are monitoring an analog input make sure you have set th...

Page 19: ...he HF Shelf EQ Set switches 1 and 2 to the positions shown below to activate the corresponding EQ levels Setting the Mid Range EQ The Mid Range EQ lets you compensate for mid range resonance or dampin...

Page 20: ...ildup To adjust the LF Shelf EQ Set switches 5 and 6 to the positions shown below to activate the corresponding EQ levels Setting the High Pass Filter The High Pass Filter lets you adjust the bass rol...

Page 21: ...g Overdriving the units for prolonged periods or not observing the warnings set out in this guide may result in failure If distortion occurs reduce the input level im mediately Both the HF and LF driv...

Page 22: ...to cool When cool turn the unit on and check for normal op eration If necessary relocate the unit to ensure adequate ventilation If the thermal shutdown activates a second time contact M Audio custome...

Page 23: ...oise input with Trim level set to 0 dB yields 90 dB 1m LF power amplifier 100 W 1 THD into 6 Ohms HF power amplifier 80 W 0 5 THD into 6 Ohms THD N 0 05 10 W into 6 Ohms Soft Limit feature Independent...

Page 24: ...SM1 Guide 18 Reference Diagrams HF Shelf EQ levels dBV 0 1 2 3 4 5 6 20 50 100 200 500 1K 2K 5K 10K 20K 40K 1 2 3 4 5 6 Hz 10 Mid Range EQ levels dBV 0 1 2 3 4 5 6 20 50 100 200 500 1K 2K 5K 10K 20K 4...

Page 25: ...A Specifications 19 LF Shelf levels dBV 0 1 2 3 4 5 6 20 50 100 200 500 1K 2K 5K 10K 20K 40K 1 2 3 4 5 6 Hz 10 High Pass Filter levels dBV 10 15 20 25 30 35 20 50 100 200 500 1K 2K 5K 10K 20K 40K 5 0...

Page 26: ...le DSM1 Guide 20 Desktop EQ 220 Hz levels dBV 0 1 2 3 4 5 6 20 50 100 200 500 1K 2K 5K 10K 20K 40K 1 2 3 4 5 6 Hz 10 Desktop EQ 175 Hz levels dBV 0 1 2 3 4 5 6 20 50 100 200 500 1K 2K 5K 10K 20K 40K 1...

Page 27: ...Appendix A Specifications 21 Desktop EQ 200 Hz levels dBV 0 1 2 3 4 5 6 20 50 100 200 500 1K 2K 5K 10K 20K 40K 1 2 3 4 5 6 Hz 10...

Page 28: ...M Audio Studiophile DSM1 Guide 22...

Page 29: ...products available Register online at www m audio com register to receive FREE product updates and for the chance to win M Audio giveaways WARNING This product contains chemicals including lead known...

Page 30: ...ML07 242A0_DSM1_UG_EN_08 08...