JS-MD 3 RES
Flight Manual Supplement
MD11-AFM-00-002
Issue: 02
Rev. 00
Rev. Date: 24-Mar-23
Page 10
–4
Cell voltage difference.
Maintenance Required
50mV during boot time and the maximum cell
voltage is higher that 4,0 V. Motor can be used
after confirming the message.
BATTERY A: Off!
Charger Error
Check Wiring
Can only happen if charger is connected. Reasons
may be:
- Communication problem between both batteries
- One battery is connected after power on.
BATTERY A: Off!
Cell Overvoltage
New Precharge. Maintenance
At least one battery cell is higher that 4,2 V. Reset
by a new precharge after problem is solved.
BATTERY A: Off!
Cell Drained
Connect Charger!
At least one battery cell voltage is below 2,3 V. It is
possible to reset this state by a new precharge
event.
BATTERY A: Off!
-Overcurrent-
Reset Power
Hardware shutoff due to high current. Reset by
power cycle.
BATTERY A: Off!
-Permanent Shutoff-
Maintenance Required
At least one battery cell voltage is < 2,0 V.
Battery is permanently shutoff.
Reset only by maintenance personal.
BATTERY A: Off!
Critical Overtemperature\ Possible
Fire! Maintenance
Battery temperature > 85°C.
Battery is permanently shutoff.
Reset only by maintenance personal.
BATTERY A:
Current too high
Decrease power setting
immediately!
Battery current > 80 A. Maybe only one battery is
connected to the power bus. Probably only one
battery is connected unintentionally. Connect only
one battery and check which one is working.
Maintenance necessary.
CHARGER:
Hardware Error
Remove Charger and try again!
General hardware error. Can only be cleared by
power reset.
CHARGER:
Overtemperature
Charger too hot. Switch charger off until it cools
down.
CHARGER:
No Battery
Charger cannot detect valid battery voltage.
CHARGER:
Charger didn’t receive control message for five