JS-MD 3 RES
Flight Manual Supplement
MD11-AFM-00-002
Issue: 02
Rev. 00
Rev. Date: 24-Mar-23
Page 5
–1
5 Emergency Procedures
This section lists the emergency procedures that may occur during
operation.
400 V Insulation Failure
Batteries are of high voltage (400 V). An Insulation Monitoring Device
(IMD or Isometer) is installed to detect any high voltage leak to the
airframe.
In case the IMD detects any voltage leakage, one of the following
warnings will be displayed to the pilot:
•
No Data from Isometer
•
Isometer defect!
•
Isometer Ground Failure!
•
Insulation Problem!!!
If any of these messages are received, switch off the RES master
switch immediately to avoid the risk of electric shock.
When on the ground, perform the following actions:
1. Stand clear of the glider and only operate the DCU
2. Switch guarded RES master switch ON while pressing the DCU
rotary command knob to enter maintenance mode
3. Extend pylon manually
4. Switch guarded RES master switch OFF
5. Remove HV batteries. Contact an approved maintenance
station to rectify the problem