6 Normal Operating Procedures
Charging and Battery Installation
6.1.1
Charging HV Batteries in the Aircraft
The HV batteries can be charged at the
pilot’s own risk inside the
aircraft using the following procedure:
1. Remove the terminal connector (located in the charge port
behind the pilot’s left elbow as shown in Figure 6-2) and
connect the Cable A charger plug to the charge port in the
fuselage (see Figure 6-1).
2. Insert a terminal connector to the unused Cable B of the battery
charger
3. Turn charger ON
4. Once the charging process is initiated, the DCU offers two
additional charge options that may be selected within 20 sec:
•
Selection of the charging power value; or
•
Selection of storage charging
Figure 6-1 Inside aircraft charging diagram (dual battery)