JS-MD 3 RES
Flight Manual Supplement
MD11-AFM-00-002
Issue: 02
Rev. 00
Rev. Date: 24-Mar-23
Page 6
–14
Inflight motor Stop Procedure
The inflight shutdown procedure is as follows:
1. Turn the command knob anti-clockwise until power shows 0 kW
The RPM will reduce and the propeller will automatically orient
into a vertical position
– two yellow arrows on each side of the
propeller will be displayed on the DCU
2. Using the rear-view mirror, visually verify the propeller is in the
vertical position
NOTE:
If the prop is not aligned in the vertical position,
momentarily apply power - the propeller performs a re-
alignment procedure and should stop in the vertical
position.
3. Push the EXT/RETR toggle switch downwards once - the
system will retract automatically
4. When the retraction process is completed, the guarded RES
master switch can be switched OFF
NOTE:
The RES can remain switched ON during flight in order
to monitor battery temperatures, or to activate the
onboard charging of the 12 V batteries