JS-MD 3 RES
Flight Manual Supplement
MD11-AFM-00-002
Issue: 02
Rev. 00
Rev. Date: 24-Mar-23
Page 10
–1
10 APPENDIX
– List of Warnings/Cautions
The following table shows the priority of the messages.
WARNINGS / ERRORS
Propeller overspeed !!!
Reduce Power
RPM >4350 U/Min. Reduce power or speed
Supply Voltage too high!
Voltage exceeds 15.0 V. Wrong battery type used
or charge control inside PRS is damaged.
Interlock Circuit not closed!!!
Check Connectors
During system startup, the interlock circuit is not
closed. Check connectors to charger and batteries.
Battery DRAINED
Connect charger!
The battery is in safety state. No motor operation is
possible.
Battery Empty
Stop Motor
The state of charge of one battery is below 2 %.
Battery TOO HOT
Stop Motor
Battery temperature is too high for operation.
Danger of permanent damage to the battery.
No Data from the charger
No CAN message from the charger.
No Data from Isometer
No CAN message from isometer. Danger of
electric shock.
Isometer defect!
Self test of isometer unsuccessful. Danger of
electric shock.
Isometer Ground Failure!
Isometer has a bad connection to LV-ground rail.
The danger of electric shock.
Insulation Problem!!!
Insulation between high voltage rail and low
voltage rail below the minimum of 100
kΩ.
Danger
of electric shock.
No Data from RFU!
No CAN message from RFU
No Data from the Motor controller No CAN message from Motor Controller
No Data from Battery A
No CAN message from left battery.