INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS
12
Pic. 5 ROOF EXIT with 90° bends
CAUTION :
if the vertical lenght is over 3 meter longer than the horizontal lenght, you will
need to place a reduction ring of
Ø 60.
Appliance
Ø 150/100 and Ø 200/130
700H / 1000H / 1150H
1300H / 1600H /1900H
for each 90° bend substract 1 m horizontaly or add 1 m verticaly.
700H/ 1000H / 1150H
1300H / 1600H/1900H
for each 45° / 30° / 15° bend substract 0,5 m horizontaly or add 0,5 m
verticaly.
Pic. 5 ROOF EXIT with 90° bends
Ø 150/100
WITH REDUCTION USVK13 ON APPLIANCE
Aplliance
A (min)
B (max)
C (min)
(A+B+C )max
700/1000 H
1,25* m
A+C+0,5m
B-A-0,5m
18m
1150 H
1,25* m
A+C+0,5
B-A-0,5
17m
1300 H
1,25* m
A+C
B-A
16m
1600 H
1,25* m
A+C-0,5m
B-A+0,5m
16m
1900 H
1,25*m
A+C-1m
B-A+1m
14m
Ø 200/130
without reduction
Appliance
A (min)
B (max)
C (min)
(A+B+C )max
700H / 1000 H
1 m
(A+C) + 8m
B-A-9m
20m
1150 H
1 m
(A+C) + 7m
B-A-8m
19m
1300 H
1 m
(A+C) + 6m
B-A-7m
18m
1600 H
1 m
(A+C) + 3m
B-A-4m
18m
1900 H
1 m
(A+C)+1m
B-A-2m
16m
WITH REDUCTION USVK13
oN APPLIANCE