Page 6 of 24
IU_PulsePRO_05
Dallas i-Button
A Dallas key can be associated to any user during user installation (function 1) by simply
entering a Dallas key after the code has been entered. User will be identified by
combination plus Dallas key. Multiple keys with the same ID can be programmed
(through PC software) and can be supplied for special applications. Dallas i-Button
models 1982, 1990 and 1971 are accepted.
Time Delay
Time delay programmable from 0 (no time delay) to 99 minutes. Open window from 1
to 19 minutes.
During time delay enabled LED flashes at two seconds intervals. Open window is
indicated by LED then buzzer at 1 seconds intervals alternately (once LED, once beep).
Time delay can be reduced only with bolt open, or waiting the counting of the time
delay already set.
Time Penalty
When entering code, a time penalty of 5 minutes will be started after the 4
th
consecutive
wrong code entered. During time penalty, LED flashes at 10s interval, no access possible
to lock.
Any key pressed during time penalty emits a long beep.
After time penalty, two consecutive wrong codes will start it again.
Battery low warning
If battery low (<6V) during motor activation, multiple beeps.
Power supply
Lock can be powered with an ALKALINE or LITHIUM 9V battery, with an internal large
battery box (6 ALKALINE 1.5V batteries) or with power supply and dedicated interface.
Audit features
Users current status can be audited through the keypad with function 7.
The lock stores the last 5.500 operations with time, date, user and operation.
Last 1.200 events can be downloaded by an i-Button with the function 7.
All the events can be downloaded directly from the lock to a PC using a USB device.
Keypads signals
Double beep if valid code/operation.
Long beep if wrong code/operation.
Long beep, plus 3 short beeps code expired.
Long bad sound if time and date lost, please insert again time and date.
Multiple beeps if battery low.
LED quickly flashing if waiting for a dual code.
LED on if in programming mode.
Summary of Contents for Basic line Series
Page 2: ...2 www m locks com...
Page 11: ...11 www m locks com Basic line V03 EN...
Page 12: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com...
Page 13: ...MiniTech High security lock for safes USER INSTRUCTIONS...
Page 32: ...2 www m locks com...
Page 46: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com...
Page 47: ...Pulse PRO High security lock for safes USER INSTRUCTIONS...
Page 48: ...Page 2 of 24 IU_PulsePRO_05...
Page 64: ...Page 18 of 24 IU_PulsePRO_05...
Page 69: ......