IU_PulsePRO_04
Page 15 of 24
Time delay (function 9)
Time delay can always be increased. In order to set up a lower time delay than the
current already set, lock must be open. If lock not opened, a counting of the time delay
will be started after the procedure, and the new values will be stored only at the end.
Press and hold
until double beep. LED remains ON:
Enter a Manager code. Double beep:
Enter the values from 00 to 99 minutes for time delay (00=disabled).
Enter the values from 01 to 19 minutes for open window. Double
beep.
Enter again the values from 00 to 99 minutes for time delay
(00=disabled) to confirm.
Enter again the values from 01 to 19 minutes for open window.
Double beep and LED goes off:
Time settings
It is strongly recommended to update time & date at least once a year.
Press and hold
until double beep. If in pre-setup mode, please
skip the next step. LED remains ON.
Enter a Manager code or a Master code. Double beep.
Press
to enter the time. Double beep.
Enter the time as this format:
hh:mm.
Double beep.
Enter again the time to confirm. Double beep and LED goes off.
Date settings
It is strongly recommended to update time & date at least once a year.
Press and hold
until double beep. If in pre-setup mode, please
Summary of Contents for Basic line Series
Page 2: ...2 www m locks com...
Page 11: ...11 www m locks com Basic line V03 EN...
Page 12: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com...
Page 13: ...MiniTech High security lock for safes USER INSTRUCTIONS...
Page 32: ...2 www m locks com...
Page 46: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com...
Page 47: ...Pulse PRO High security lock for safes USER INSTRUCTIONS...
Page 48: ...Page 2 of 24 IU_PulsePRO_05...
Page 64: ...Page 18 of 24 IU_PulsePRO_05...
Page 69: ......