6
www.m-locks.com
Next, press all keys one by one and one after the other.
1
2
3
4
5
6
7
8
9
0
If the key = OK
If the key = not OK , the test will be aborted.
If one or more keys do not operate properly, please contact your supplier.
b. Mechanical test
The door has to be open during the checking procedure!
With the lock closed, turn the handle in the opening direction as far as it will go. Enter the code and
then try to rotate the handle further in the opening direction. This should not succeed. Therefore, first
turn the handle to the fully closed position and turn it back in the opening direction immediately. Now
the lock should open easily.
This entire sequence has to be carried out quite quickly, since the electronics allow an opening only
within 4 seconds.
Then turn the handle back to the fully closed position. Now it should not be possible to open the lock
without code input. After entering a valid code, the lock should now be easy to open and close again.
Standard (Right Hand) opening
Left Hand opening
Repeat the mechanical test several times before locking the door!