background image

5

www.m-locks.com

Basic line

V02

EN

!

  

Caution!

•   The lock has been designed for use in a temperature range from +10˚C to +50˚C and a non-

condensing humidity range from 30% to 80%. 

•  It may only be cleaned with a moist cloth (do not use aggressive cleaning agents).
•  The lock may only be installed by qualified fitters.
•  The lock may not be lubricated.
•   Never open the lock housing. If it is necessary to disassemble the hardware, only do so in accord-

ance with the technical instructions. If you fail to do so, the lock may no longer function properly 
and you will forfeit your right to warranty.

2

   SYMBOLS AND SIGNALS

double audible tone, 

correct 

entry

LED 

flashes

1

   

2

 ...

digit on keypad

long audible tone, 

incorrect 

entry

LED 

illuminated

press and hold

OPENING THE LOCK

1

   

2

   

3

   

4

   

5

   

6

  

Enter the code (Manager Code set at the factory = 1-2-3-4-5-6), if the code is correct, a double signal 
sounds, you can now unlatch the door and open it. If the door is not opened within 3 seconds, the lock 
will automatically engage again.  

EM3020

: to close the lock, press any key.

OPEN WITH TIME DELAY

For example!

1

   

1

   

1

   

1

   

1

   

1

  

 

Enter the code (i.e. 1-1-1-1-1-1), after entering a right code, a double signal sounds
and time delay starts. During time delay expires, the light flashes every 10 seconds. After time delay 
has elapsed, a double signal sounds and the open window starts.

Summary of Contents for EM1620

Page 1: ...Basic line EM1620 EM2020 EM2520 EM3020 EM3520 M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com User manual V02 EN...

Page 2: ...2 www m locks com...

Page 3: ...8 Setting the time delay and opening window time8 9 Deleting the delay setting 10 Replacing the battery 11 Troubleshooting The world of M LOCKS M LOCKS has extensive experience in this field and is a...

Page 4: ...nd you will hear a long tone when attempting to make an entry Entering an incorrect code on two further occasions after the keypad has been re enabled will trigger a new keypad lock out period of 5 mi...

Page 5: ...t to warranty 2 SYMBOLS AND SIGNALS double audible tone correct entry LED flashes 1 2 digit on keypad long audible tone incorrect entry LED illuminated press and hold 3 OPENING THE LOCK 1 2 3 4 5 6 En...

Page 6: ...e the lock is secured again with time delay If the lock is set to dual combo one valid code starts time delay During the open window two valid codes have to be entered to open the lock Press a random...

Page 7: ...gnal sounds and the old code remains valid 7 DELETE SECOND USER 3 Press and hold 3 until a double signal sounds The LED will illuminate when performing the following actions 9 8 7 6 5 4 Enter your per...

Page 8: ...lay setting and opening window time again 9 DELETING THE DELAY SETTING The delay setting can only be changed or deleted during the open window time 1 1 1 1 1 1 Enter a valid code After the delay perio...

Page 9: ...de until the lock opens completely 11 TROUBLESHOOTING The lock does not react a Check the keypad If the lock does not react follow the procedure below to check that your keypad is working 5 Press and...

Page 10: ...n This is probably a problem with the lock bar mechanism inside the safe door and not a problem of the lock itself This manual only relates to the lock and not the complete safe Please contact the man...

Page 11: ...11 www m locks com Basic line V02 EN...

Page 12: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com...

Reviews: