background image

15

www.m-locks.com

Multi Level Software Locks

V03

EN

19

 TROUBLESHOOTING

The lock does not react

a.  Check the keypad

If the lock does not react, first follow the procedure below, to check if your keypad is working.

   

5

 

 

Press and hold key ‘5’ until a double signal sounds. The LED will illuminate when performing the 
following actions:

1

   

2

   

3

   

4

   

5

   

6

 

7

   

8

   

9

   

0

 

Press all the keys one by one. If the key is OK a double signal sounds, if the key is not OK, a long signal 
sounds. the test will be aborted.
If one or more keys do not operate properly, please contact your supplier.

b.  The lock does not emit any audible tones at all

The lock does not emit an audible tone when a key is pressed. The battery is exhausted, replace the 
battery. See point 18.

c.  I have forgotten my code

For security reasons, M-LOCKS does not provide a code that you can use to open your lock. 
Please contact your supplier.

The lock is difficult to move and open

This is probably a problem with the lock bar mechanism, inside the safe door, and not a problem of the 
lock itself. This manual only relates to the lock and not the complete safe. Please contact the manufac-
turer of the safe in order to resolve this problem.

Summary of Contents for EM3050

Page 1: ...Multi Level Software Locks EM2050 EM3050 EM3550 M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com User manual V03 EN...

Page 2: ...2 www m locks com...

Page 3: ...lay 6 Changing code 7 Activating silent alarm MANAGER INSTRUCTIONS 8 Activating users 9 Activating users with dual mode 10 Activating users with Dallas key 11 Disabling enabling users not active in du...

Page 4: ...code and open the lock The lock works with a six digit code In some cases it may be that the lock requires a 7 digit code For simplicity it is mentioned only one operation with 6 digit code in this gu...

Page 5: ...1 1 1 1 1 a double signal sounds you can now open the lock unlock the door and open it If the lock is not opened within 3 seconds the lock will automatically lock again Caution The lock has been desig...

Page 6: ...again EM3550 EM40450 Enter codes i e 1 1 1 1 1 1 and 2 2 2 2 2 2 After entering right codes a double signal sounds you can now open the lock unlock the door and open it If the lock is not opened with...

Page 7: ...e lock is secured again with time delay If the lock is set to dual combo one valid code starts time delay During the open window two valid codes have to be entered to open the lock Press a random key...

Page 8: ...xample 2 2 2 2 2 3 In case of a hold up situation a silent alarm can be sent by entering the last digit 1 If the last number is a 9 you have to enter 0 to send a silent alarm For example Valid code 2...

Page 9: ...onal Manager Code 1 Enter User ID 1 9 only if more than 1 user is programmed 1 1 1 1 1 1 Enter the new User Code 1 1 1 1 1 1 Enter the new User Code again 9 ACTIVATING USERS IN DUAL MODE IF MANAGER IS...

Page 10: ...d hold 1 until a double signal sounds The LED will illuminate when performing the following actions For example 9 8 7 6 5 4 Enter your personal Manager Code 1 Enter User ID 1 9 only if more than 1 use...

Page 11: ...until a double signal sounds The LED will illuminate when performing the following actions For example 9 8 7 6 5 4 Enter your personal Manager Code 1 Enter User ID of the user that has to be deleted T...

Page 12: ...he time delay values can only be done in open window time 9 Press and hold 9 until a double signal sounds The LED will illuminate when performing the following actions For example 9 8 7 6 5 4 Enter th...

Page 13: ...4 Enter the Manager Code 0 0 0 1 Delete the delay and open window time by entering 00 for the delay setting and 01 for the open window time 0 0 0 1 Enter the delay setting and open window time again 1...

Page 14: ...audit gives a chronological list of users that has opened the lock 18 REPLACING THE BATTERY If the lock emits a series of audible tones when opened the battery is almost exhausted and must be replaced...

Page 15: ...If one or more keys do not operate properly please contact your supplier b The lock does not emit any audible tones at all The lock does not emit an audible tone when a key is pressed The battery is...

Page 16: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com...

Reviews: