The diameter of the cable hole should be minimum 9 mm, maximum 12 mm. The
spindle hole should be maximum
Ø
13 mm. Both holes must be deburred well to
avoid damage.
Adjust position and mount the entry
unit with M4 flathead screws.
Insert the shaft plate into the
housing and push the shaft into the
lock
.
If the handle drives a boltwork,
put the star washer on the end of
the shaft to secure the handle.
Keep the inside of the housing clean (remove dust). Route
the cable through the cable hole. Route the battery cable in
the opposite direction through the cable hole and push the
white connector into the receptacle on the circuit board.
Make sure the connector is completely seated.
Battery box ST50•65
Remove the protective layer from the adhesive ring on the back of the keypad unit.
Position the keypad and press it into the housing.
Make sure the surfaces are dry
and clean, and no cables are in the way. Do not remove and re-apply keypad
once it has been glued in the housing!
Vlijtstraat 40, NL-7005 BN Doetinchem
Tel: +31 314 376 876 Fax: +31 314 376 878
www.m-locks.com / info@m-locks.com
Only use DURACELL PROCELL 9V-ALKALINE- or Energizer batteries.