background image

EC10•70 Technical Manual 

 

 

 

The diameter of the cable hole should be minimum 9 mm, maximum 12 mm.  The 

spindle  hole  should  be  maximum 

Ø

  13  mm.    Both  holes  must  be  deburred  well  to 

avoid damage. 

Adjust position and mount the entry 

unit with M4 flathead screws.

Insert  the  shaft  plate  into  the 

housing and push the shaft into the 

lock

.

If the handle drives a boltwork, 

put  the  star  washer  on  the  end  of 

the shaft to secure the handle.

Keep the inside of the housing clean (remove dust). Route 

the cable through the cable hole.  Route the battery cable in 

the opposite direction through the cable hole and push the 

white connector into the receptacle on the circuit board. 

Make sure the connector is completely seated. 

      Battery box ST50•65 

Remove the protective layer from the adhesive ring on the back of the keypad unit. 

Position the keypad and press it into the housing.

  Make sure the surfaces are dry 

and clean, and no cables are in the way.  Do not remove and re-apply keypad 

once it has been glued in the housing! 

Vlijtstraat 40, NL-7005 BN Doetinchem 

Tel: +31 314 376 876  Fax: +31 314 376 878 

www.m-locks.com /  info@m-locks.com

 

 

 

Only use DURACELL PROCELL 9V-ALKALINE- or Energizer batteries.

Reviews: