ROTOBOLT DIMENSIONS 

 

 
Insert  the  keypad  cable  into  the  “ENT”  connector  of  the  lock.  Check  that  the  cable  is 
completely seated (to remove it lift it up and carefully pull it out).  
 
Battery box or alarm interfaces will be connected to the “BAT” connector of the lock. 
 
Tie cables away from moving parts. 
 
Connect  a  9V-ALKALINE  battery  and  repeat  functional  test  (with  door  open)  several  times 
before locking the safe door. 
 
STRAIGHTBOLT LOCK 
 

In  the  LOCKED  position,  there  should  be  approximately  1mm  clearance 
between the lock bolt and the cavity in the blocking bar of the boltwork. The 
lock bolt must move freely into the cavity.   

 

 
 
In  OPEN  position,  there  should  be  minimum  3mm  and 
maximum 5mm clearance between the lock bolt and the 
blocking bar of the boltwork. 
 

The force applied to the bolt must not exceed 1kN.  
 
Only use M-Locks supplied screws to mount the lock. Tighten the screws securely so the lock 
body  is  attached  firmly  to  the  mounting  surface.  Do  not  overtorque  mounting  screws. 
Maximum torque 3.5Nm.  
 
 
 
 