User instructions
MiniTech
Dallas keys
Available as option for Manager and users (not for Master).
Power supply
Lock can be powered with:
an ALKALINE 9V battery located in the battery compartement below the keypad;
an internal battery box
.
A power adapter (ref. N1212) with power supply interface (ref. T6005/W or T6005)
.
Low battery warning
A long beep together with the message “LOW BATTERY” on the display, indicate a low battery
level which needs immediate replacing.
Audit
The lock is able to save the last 5500 operations with time, date, user and operations
description.
Silent alarm
With this function enabled, enter an opening code increasing or decreasing by one number
the last code digit (ex. 03-030304 or 03-030302 instead of 03-030303): the lock opens and
simultaneously the output of the alarm interface or I/O interface is activated.
IMPORTANT
Some options/characteristics reported in this user manual, can only be used if previously
enabled through the setup software. Thus, please refer to the user manual
IU_Minitech_setup_XX.
Please contact
service@m-locks.com
for further information.
Lock opening
Manager (01) and users (02-49):
Power up the keypad and enter an opening code. LCD shows:
OPEN
Open the lock within 3 seconds.
Override users (50-59):
Power up the keypad and enter an override user code. LCD shows:
OPEN
Open the lock within 3 seconds.