background image

4

www.m-locks.com

MOUNTING INSTRUCTIONS

The VdS recognition of this lock is based on this mounting instruction. Read carefully.

The force applied to the lock bolt should not exceed 1 KN. If higher force is applied, please consult with 
the testing institute (i.e. UL, VdS). Only use supplied screws to mount the lock. Fix the lock handtied.
The maximum allowed cable/spindle-hole diameter is 11mm (if located under the lock body)
Position of the cable hole depends on which entry unit is used.

The lock has to be fitted exclusively on steel secure storage. The mounting base also must be made of 
steel . Installation on other materials only after consultation M - LOCKS or  VdS .

It is recommended to prevent access to unauthorized persons to safety-relevant parts of the high-
security lock when the safe is open . Par example by a with a screws fixed  interior cover.

The lock housing must be protected against destructive attacks from outside with suitable protective 
materials .

Summary of Contents for Rotobolt EM2020

Page 1: ...Rotobolt EM2020 EM2050 M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com Mounting instructions V03 EN ...

Page 2: ...2 www m locks com EM2020 EM2050 ...

Page 3: ... we are asking you to touch the metal surface of the safe for discharging before operating the lock Caution The lock has been designed for use in a temperature range from 10 C to 50 C and a non condensing humidity range from 30 to 80 It may only be cleaned with a moist cloth do not use aggressive cleaning agents The lock may only be installed by qualified fitters The lock may not be lubricated Nev...

Page 4: ...er is 11mm if located under the lock body Position of the cable hole depends on which entry unit is used The lock has to be fitted exclusively on steel secure storage The mounting base also must be made of steel Installation on other materials only after consultation M LOCKS or VdS It is recommended to prevent access to unauthorized persons to safety relevant parts of the high security lock when t...

Page 5: ... work part that is moving the lock bolt should be approximately 1 mm Only use supplied screws to mount the lock Tighten the screws securely so the lock body is attached firmly to the mounting surface Maximum Torx 5 5 Nm 5 MOUNTING INSTRUCTIONS Mount the entry unit following the manufacturer s instruction Insert the connector of the entry unit in the outer ENT position Connect battery alarm box con...

Page 6: ...ing the safe door Check the keypad If the lock does not react follow the procedure below to check that your keypad is working Press and hold key 5 until you hear a double tone The LED will illuminate when performing the fol lowing actions 5 Next press all of the keys in one by one and one after the other 1 2 3 4 5 6 7 8 9 0 If the key OK If the key not OK the test will be aborted If one or more ke...

Page 7: ...ISCH EM2020 EM2020 S EM2050 EM2050 S EM2050 AB Power supply 9V Alkaline Duracell Duracell Industrial or other oder Energizer block batteries Codes 2 6 digits Up to 10 6 or 7 digits Up to 10 6 or 7 digits Manager Codes 1 1 1 User Codes 1 Up to 9 Up to 9 Time delay open window 01 99 min 01 19 min 01 99 min 1 19 min 01 99 min 1 19 min Battery low signal Yes Yes Yes Dallas key and code Dallas key and ...

Page 8: ...M LOCKS BV Vlijtstraat 40 7005 BN Doetinchem The Netherlands www m locks com ...

Reviews: