3
www.m-locks.com
Rotobolt
V03
EN
1 §
IMPORTANT INSTRUCTIONS
• Before mounting the lock, please read the instructions for use carefully.
• Ensure that you
only
program the lock when the
safe is open
.
After changing the code, always try the code several times with the safedoor open.
•
Only after several positive function test (opening / closing) the safedoor can be closed.
• Each key entry is confirmed by an audible tone and visual signal. These signals are not referred to in
the description that follows.
• You have a maximum of 10 seconds for each key entry. If you do not make an entry via the keypad
during this period of 10 seconds, the entry procedure will automatically abort. You must then start
again from the beginning.
• After entering a valid code, you will hear two audible tones. An invalid entry will trigger a long tone.
• If you accidentally enter an invalid code at the first attempt, you must wait 20 seconds before you
re-enter the code.
• Our products fulfil the EN1300 requirements regarding resistance against electrostatic charge.
In fact it may happen that the electrostatic charge of a user exceeds the extreme value many
times.That’s why we are asking you to touch the metal surface of the safe for discharging before
operating the lock.
!
Caution!
• The lock has been designed for use in a temperature range from +10˚C to +50˚C and a non-
condensing humidity range from 30% to 80%.
• It may only be cleaned with a moist cloth (do not use aggressive cleaning agents).
• The lock may only be installed by qualified fitters.
• The lock may not be lubricated.
• Never open the lock housing. If it is necessary to disassemble the hardware, only do so in
accordance with the technical instructions. If you fail to do so, the lock may no longer function
properly and you will forfeit your right to warranty.
2
CHARACTERISTICS
The Rotobolt lock can be mounted in all four mounting directions. Also, by flipping the lock, all blocking
directions can be achieved. The mounting dimensions are standard. The lock is delivered with metric
(M6) mounting screws.
The electronics feature a 6- digit main code (in some cases it may be that the lock requires a 7-digit
code) that can be changed by the user. With the main code usercode(s) can be activated and deleted.
If a valid code has been entered, the lock electronics removes the blocking for 3 seconds and the
boltwork can be moved into OPEN position by pushing the bolt inside the lock case. When moving the
boltwork into LOCKED position the Rotobolt automatically secures.