ROTOBOLT DIMENSIONS
Insert the keypad cable into the “ENT” connector of the lock. Check that the cable is
completely seated (to remove it lift it up and carefully pull it out).
Battery box or alarm interfaces will be connected to the “BAT” connector of the lock.
Tie cables away from moving parts.
Connect a 9V-ALKALINE battery and repeat functional test (with door open) several times
before locking the safe door.
STRAIGHTBOLT LOCK
In the LOCKED position, there should be approximately 1mm clearance
between the lock bolt and the cavity in the blocking bar of the boltwork. The
lock bolt must move freely into the cavity.
In OPEN position, there should be minimum 3mm and
maximum 5mm clearance between the lock bolt and the
blocking bar of the boltwork.
The force applied to the bolt must not exceed 1kN.
Only use M-Locks supplied screws to mount the lock. Tighten the screws securely so the lock
body is attached firmly to the mounting surface. Do not overtorque mounting screws.
Maximum torque 3.5Nm.