are ready to se t the switches f or serial
communication .
Serial Dead-End
– No other de vice connec ted to
this serial por t. Use the KLI C layou t diagram to
locate switch banks.
Note :
“0 ”
indicates
open/off
Bank #1
“1” indicate s close d/on
Switch #
12345678
See
ASCII /Ti ming
Ch ar t
Bank #2
*Ba u d R a te Cha r t
Switch #
12345678
Sw i tch #
Ba u d
***00000
123
Bank #3
111
19200
Switch #
12345678
011
9600
00000000
101
4800
Bank #4
001
2400
Switch #
12345678
110
1200
00011111
010
600
100 300
000
N o t U se d
Serial Pa rasite
– A printer or other de vice is used
on this port. Use KLIC layout diagram to locate
switch bank s.
Note :
“0 ”
indicates
open/off
Bank #1
“1” indicate s close d/on
Switch #
12345678
See
ASCII /Ti ming
Ch ar t
Bank #2
*Ba u d R a te Cha r t
Switch #
12345678
Sw i tch #
Ba u d
***00000
123
Bank #3
111
19200
Switch #
12345678
011
9600
00000000
101
4800
Bank #4
001
2400
Switch #
12345678
110
1200
00011000
010
600
101 300
000
N o t U se d
Parallel
Par allel communication with the cash drawer
involves sending a unique drawer opening
charac ter . An y on e of the stan dard ASCII
charac ter code s may be use d as a dr awer
opening char acter as de ter mine d by prefer ence
or the sof tware being use d. A f avorite i s the
CONTROL G (ASCII 7). CONTROL G is of ten used
because it is also the bell charac ter an d man y
ter minals e mi t a sh ort beep as the drawer opens.
You may also require an “ESC” prefix to the
drawer opening by setting switch 8 of bank #1 to
on . This re quires that th e “ESC” ch aracter
imme diate ly prece de your drawer opening
charac ter to be recognized by th e dr awer .
The other c onsi deration f or paralle l
communication is wh ether the cash dr awe r will
be use d in Dead En d mode or in Parasite mode .
Using Dead End mode mean s that the cash
drawer is the on ly de vice connecte d to the
par alle l por t. I f you will be using a pr inter,
multiple c ash drawers, or other devices
connecte d to the same par allel por t, use the
Par asite mode . * NOTE: When a cash dr awer is
the last de vice in th e chain, it mu st be set in
Dead En d mode .
Ar me d with these two pieces of infor mation –
opening ch arac ter an d mode , you are ready to
set the switches f or paralle l communication .
Parallel Dead-End
– No other de vice use d on this
por t. Use KLI C layou t diagram to loc ate switch
bank s.
Note :
“0 ”
indicates
open/off
“1”
indicate s
close d/on
Bank #1
Switch #
12345678
See
ASCII /Ti ming
Ch ar t
Bank #2
Switch #
12345678
00011111
Bank #3
Switch #
12345678
11111111
Bank #4
Switch #
12345678
11100000
Parallel Para site
– A printer or other de vice is
used on this port. Use KLI C layou t diagr am to
locate switch banks.
Note :
“0 ”
indicates
open/off
“1”
indicate s
close d/on
Bank #1
Switch #
12345678
See
ASCII /Ti ming
Ch ar t
Bank #2
Switch #
12345678
00000000
Bank #3
Switch #
12345678
11111111
Bank #4
Switch #
12345678
11100000
Pulse
(Serial Mode )
Pulse communication with the c ash dr awer
involves sending a positive going pu lse si gnal
from the compu ter on pin 2 (Tran smi t Data (TXD)).
The sign al sh ould be nor mally low (less the n 2.5
volts) and should switch momentarily hi gh to
greater th an 3 .5 volts to open the dr awer .
Pulse Mode
– No othe r de vice use d on this por t.
Use KLI C layou t diagram to locate switch banks.
Note :
“0 ”
indicates
open/off
“1”
indicate s
close d/on
Bank #1
Switch #
12345678
See
ASCII /Ti ming
Ch ar t
Bank #2
Switch #
12345678
00000000
Bank #3
Switch #
12345678
00000000
Bank #4
Switch #
12345678
Se t ON to se nd draw e r
00011000*
ope n/cl ose d status to
computer on pi n 6 Data
Se t R e a dy ( DSR ).