MS-4K71-12TR USER GUIDE
11
support@m4sol.com | www.m4sol.com
GUI Settings
Network Function
COMMUNICATION SETUP
Move the main menu cursor to [COMMUNICATION SETUP], and press
[HOME] key enter the communication setup page, as shown in the following
figure. Protocol: Control protocol type, optional items: Auto, VISCA, PELCO-D,
PELCO-P. V_Address: Optional items: 1 ~ 7. (Effective only in Auto, VISCA
protocol). V_AddrFix: Optional items: On, Off (When set to On, useless in 88
30 01 FF Command). P_D_Address: Optional items: 0 ~ 254. (Effective only in
Auto, PELCO-D protocol). P_P_Address: Optional items: 0 ~ 31.
(Effective only in Auto, PELCO-P protocol). Net Mode: Set the serial port
network control, optional items: Serial, Paral. Baudrate: Serial port baud rate,
optional items: 2400, 4800, 9600, 38400.
RESTORE DEFAULT
Move the main menu cursor to [RESTORE DEFAULT], and press [HOME]
key enter the restore default page, as shown in the following figure. Restore:
Confirm restore factory settings, optional items: Yes, No. Note: Press [HOME]
button to confirm, all parameter restore default, include IR Remote address
and VISICA address.
Operating Environment
Operating System: Windows 7/8/10, Mac OS X, Linux, Android
Network Protocol: TCP/IP
Client PC: P4/128M RAM/40G HDD/ support
scaled graphics card, support DirectX 8.0 or more advanced version.
Equipment Installation
1) Connect video conference camera to your internet or to your PC via network cable.
2) Turn on DC 12V power.
3) If the network connection is normal, the connection light (green) at the network interface will light up within 5
seconds, and the data indicator (orange) will flash, indicating that the physical connection of the camera has been
completed.
Internet Connection
There are two main ways to connect video conference camera.
Connect by Network Cable
Connect by Switch/Router