background image

MS-4K71-12TR USER GUIDE

09

support@m4sol.com | www.m4sol.com

Serial Communication Control

GUI Settings

•  RS232 Communication Control

The camera is controlled via RS232. The RS232 serial port parameters are as follows:

Baud rate: 2400/4800/9600/38400;

Starting position: 1 bit

Data bit: 8 bits

Stop bit: 1 bit

Check digit: None

•  RS485 Communication Control

Control camera via RS485, half duplex mode:

Baud rate: 2400/4800/9600/38400;

Starting position: 1 bit

Data bit: 8 bits

Stop bit: 1 bit

Check digit: None

After power on, the camera goes to the upper right limit and then back to the middle position. The zoom lens is pulled 

to the farthest position, auto focus, and the aperture is adjusted to the default value. If the camera has preset 0 saved, 

the camera will be set to position 0 after the initialization is completed. At this point, the user can use the serial port 

command to control the camera.

•  List of protocols (omitted)

The serial port of the camera follows the VISCA/Pelco-D/Pelco-P standard protocol. If secondary development is 

required, the camera can be controlled according to the standard protocol.

MENU

Press [MENU] button to display the main menu on the normal screen, using 

arrow button to move the cursor to the item to be set. Press the [HOME] 

button to enter the corresponding sub-menu.

EXPOSURE

Move the main menu cursor to [EXPOSURE], and press [HOME] key enter the 

exposure page, as shown in the following figure.

Mode: Exposure mode, optional items: Auto, Manual, SAE, AAE, Bright.

ExpCompMode: Exposure the compensation mode, optional items: On, Off 

(Effective only in Auto mode).cExpComp: Exposure the compensation value, 

optional items: -7 ~ 7 (Effective only in ExpCompMode item to On).

Backlight: Set the backlight compensation, optional items: On, Off (Effective 

only in Auto mode). Bright: Intensity control, optional items: 0 ~ 17 (Effective 

only in Bright mode). Gain Limit: Maximum gain limit, optional items: 0 ~ 

15 (Effective only in Auto, SAE, AAE, Bright mode). Anti-Flicker: Anti-flicker, 

optional items: Off, 50Hz, 60Hz (Effective only in Auto, AAE, Bright mode).

Meter: Optional items: Average, Center, Smart, Top. Iris: Aperture value, 

optional items: F1.8, F2.0, F2.4, F2.8, F3.4, F4.0, F4.8, F5.6, F6.8, F8.0, F9.6, F11.0, 

Close (Effective only in Manual, AAE mode). Shutter: Optional items: 1/30, 

1/60, 1/90, 1/100, 1/125, 1/180, 1/250, 1/350, 1/500, 1/725, 1/1000, 1/1500, 1/2000, 

1/3000, 1/4000, 1/6000, 1/10000 (Effective only in Manual, SAE mode). Gain: 

Optional items: 0 ~ 7 (Effective only in Manual mode). DRC: DRC strength, 

optional items: 0 ~ 8.

Summary of Contents for MS-4K71-12TR

Page 1: ...User Guide MS 4K71 12TR Integrated UHD Tracking Camera Revision 1 0 March 2022 ...

Page 2: ...data over Cat cables are measured using TE CONNECTIVITY 1427071 6 EIA TIA 568 B termination T568B of cables is recommended for optimal performance To minimise interference of unshielded twisted pairs in the CAT5e 6 cable do not run the Cat5e 6 6a cabling with or in close parallel proximity to mains power cables Do not substitute or use any other power supply other than the enclosed unit or an MSol...

Page 3: ...Integrated design can output panoramic and close up multi channel HD video at the same time Intelligent Tracking Built in image recognition and tracking algorithms without any prior auxiliary camera positioning or tracking of the host achieves a smooth and natural tracking effect Adjustable Viewing Angle The viewing angle of the panoramic camera can adjust vertically 15 0 making it convenient for ...

Page 4: ...04 support m4sol com www m4sol com MS 4K71 12TR USER GUIDE Connectivity Overview ...

Page 5: ... m4sol com www m4sol com Product Installation When the monitor thickness is 170mm or when it is required to be mounted on a wall the wall mounting method can be selected The specific installation steps are shown in the following figure ...

Page 6: ...R GUIDE Interface and Buttons Dimensions 1 Network Interface 2 USB 2 0 Interface 3 RS232 IN Interface 4 RS232 OUT Interface 5 RS485 Interface 6 HDMI Interface 7 LINE IN Interface 8 3G SDI Interface 9 USB 3 0 Interface 10 DC 12V Interface 11 Power Switch ...

Page 7: ... of the Pan Tilt Simultaneously press L R Set 1 STD set the Pan Tilt turn the same direction as the L R Set Simultaneously press L R Set 2 REV set the Pan Tilt turn the opposite direction as the L R Set 9 Focus Key Used for focus adjustment Press AUTO adjust the focuses on the center of the object automatically Press MANUAL adjust the focus on the center of the object manual MANUAL button and adju...

Page 8: ...lay Freeze on the left upper corner character after five seconds display disappear automatically If you want to cancel the freeze press F4 key and then can return to normal display Unfreeze on the left upper corner after five seconds display will disappear automatically Recalling the Preset image Freeze By the OSD Menu Image Freeze to set recalling the preset image freeze function After the functi...

Page 9: ... the main menu on the normal screen using arrow button to move the cursor to the item to be set Press the HOME button to enter the corresponding sub menu EXPOSURE Move the main menu cursor to EXPOSURE and press HOME key enter the exposure page as shown in the following figure Mode Exposure mode optional items Auto Manual SAE AAE Bright ExpCompMode Exposure the compensation mode optional items On O...

Page 10: ...W Mode Optional items On Off Gamma Optional items EXT PC 0 45 0 5 0 56 0 63 Style Optional items Default Outdoor Cozy Norm Bright PC LDC Optional items Off 10 10 P T Z Move the main menu cursor to P T Z and press HOME key enter the P T Z page as shown in the following figure SpeedByZoom The depth of field scale switch optional items On Off AF Zone Interested in focusing area optional items Top Cen...

Page 11: ...nu cursor to RESTORE DEFAULT and press HOME key enter the restore default page as shown in the following figure Restore Confirm restore factory settings optional items Yes No Note Press HOME button to confirm all parameter restore default include IR Remote address and VISICA address Operating Environment Operating System Windows 7 8 10 Mac OS X Linux Android Network Protocol TCP IP Client PC P4 12...

Page 12: ...e camera IP address will be shown on screen Method 2 Connect camera to PC with network cable use upgrade_En exe to search for IP address Change IP address two methods as below Method 1 Login the web page select Network Lan Settings change IP address subnet mask and gateway Click Apply and restart the camera Method 2 Open upgrade_En exe change IP and click Set After modified the video conference ca...

Page 13: ...t username admin password admin shown as below After login shown as below If user first time use this camera by internet only for new user must install a player software VLC Please go to VLC website http www videolan org vlc download and Install the 32 bit VLC player software After installation login again will show as above Camera Controlled by WAN Setup IP Controlled by Dynamic DNS Two dynamic D...

Page 14: ... rtsp ip port number 1 First stream rtsp ip port number 2 Second stream Step 4 Click Play RTSP port number default 554 If the camera port default is 80 then unnecessary to input port number of URL address Camera Parameter Setup Homepage Introduction Menu All pages include two menu bars Real time monitoring displaying video image Parameter setup with function buttons Video Viewing Window Video view...

Page 15: ...ve presets for quick recall of these positions Type a number between 0 and 254 into the Preset box Click the Set button to save the current location with that preset number Click the Call button to cause the camera to return to that position This enables smooth quick and convenient control without the need to manually drive the camera You can set up preset that user want as below Method 1 Type a n...

Page 16: ...ger of the bit rate the clearer of the image However the configuration of the bit rate needs to be combined with the network bandwidth When the network bandwidth is narrow and the bit rate is configured larger the video stream cannot be transmitted normally and the visual effect is worse 5 Frame Rate User can specify the size of the frame rate generally the frame rate greater the image more smooth...

Page 17: ...15 slider control on the right shows the corresponding numerical Default value is auto 5 Hue Hue 0 14 slider control on the right shows the corresponding numerical Default value is 7 6 Flip Mirror Tick Flip to realize image upside down tick mirror to realize image around the mirror Default value is not tick Audio Settings 1 Audio Switch Enable or disable audio switch 2 Audio Type Audio type AAC 3 ...

Page 18: ...t RTSP protocol use the VLC tools broadcast default port 554 C PTZ Port Support PTZ protocol default port 5678 D UDP Port Support UDP protocol default port 1259 3 Control Protocol Settings Setting the camera control communication protocol include Visca address Pelco D address and Pelco P address 4 RTMP S Settings Setting the MRL of RTMP select enable or disable video and audio You can select contr...

Page 19: ...ion be stabled 2 Check whether have vibrating machinery or object near the camera There is no video image in IE Browser Please visit VLC website http www videolan org vlc download and install the 32 bit VLC media player after it installed visit video conference camera will have normal image display Unable to access video conference camera through IE Browser 1 Using PC to access the network to test...

Page 20: ...ture 4 F to 140 F 20 C to 60 C Operating humidity 0 80 non condensing Host USB C connectivity 1 x USB C female host USB control 1 x Micro USB female RS 232 connectivity 1x 3 pin phoenix connector block included Power supply PoC 1x 12V 2A DC Individual unit dimensions W x D x H 60 x 84 x 25mm Individual unit weight 0 2kg Operating temperature 32 F to 104 F 0 C to 40 C Storage temperature 4 F to 140...

Page 21: ...www m4sol com ...