EM-9441-A  Rev.9  P. 1 / 9

INSTRUCTION MANUAL

BARGRAPH INDICATING ALARM

(with 4-digit digital meter; with isolated DC output)

MODEL

48NDVA

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Bargraph indicator (incl. scale plate) .................................(1)
Mounting bracket ................................................................(2)
Bezel*

1

..................................................................................(2)

Watertight packing .............................................................(1)
*1. The size of included bezel differs depending on option code.

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.
For detailed explanations to operate and program the 
module, please refer to Model 48NDVA Operating Manual 
(EM-9441-B), downloadable at M-System’s web site: http://
www.m-system.co.jp.

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• This equipment is suitable for Pollution Degree 2, Meas-

urement category II (alarm output, transient voltage 
2500V) and Installation Category II (transient voltage 
2500V).  Reinforced insulation (signal input to alarm out-
put to power input and DC output to power input: 300V) 
is maintained.  Prior to installation, check that the insu-
lation class of this unit satisfies the system requirements.

• The equipment must be mounted on a panel surface.  

Once mounted on a panel, take appropriate precautions 
to prevent operators to be exposed to the terminal block.

• Altitude up to 2000 meters.
• Insert a noise filter for the power source connected to the 

unit.  TDK-Lambda Noise Filter Model RSAN-2006 or 
equivalent is recommended.

• The equipment must be installed such that appropriate 

clearance and creepage distances are maintained to con-
form to CE requirements.  Failure to observe these re-
quirements may invalidate the CE conformance.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

• In order to enable the operator to turn off the power in-

put immediately, install a switch or a circuit breaker ac-
cording to the relevant requirements in IEC 60947-2 and 
properly indicate it.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

    100 – 240V and 85 – 264V AC rating: 85 – 264V, 
     

 

50/60 Hz, approx. 5.5 – 8VA

    24V DC rating: 24V ±15%, approx. 3.5W

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and input signal for safety.

• Be sure to put the terminal cover on while the power is 

supplied. 

 

ENVIRONMENT

• Indoor use.
• If the unit’s environmental protection is compromised 

(e.g. when multiple units are to be mounted side by side) 
when heavy dust or metal particles are present in the air, 
install them inside an enclosure with a proper ventila-
tion.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +55°C     

(23 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 

REQUIREMENTS TO ENSURE IP65

• Observe the designated panel cutout size (31.5 × 138 mm).
• Single mounting only.  IP65 is not ensured when the units 

are clustered side by side.

• The watertight packing included in the product package 

must be placed behind the front cover.

• The mounting bracket must be fastened tightly until they 

hit the panel.

• Confirm visually that the packing is not contorted or ex-

cessively run off the edge after installation.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

 

TERMINAL BLOCK

• The terminal block is separable in two pieces.  Loosen two 

screws on top and bottom of the terminal block to sepa-
rate.

• Be sure to turn off the power supply, input signal and 

power supply to the output relays before separating the 
terminal block.

Terminal Block

Separable

Terminal Block Screw
(top & bottom)

Summary of Contents for 48NDVA

Page 1: ...cted wires may af fect the protection level of this unit when it is integrated in a panel system The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conform ity In order to enable the operator to turn off the power in put immediately install a switch or a circuit breaker ac cording to the relevant requirements in ...

Page 2: ...STERED MOUNTING Not conform to degree of protection IP65 1 0 61 5 min USING BEZELS Bezels are used when the unit needs to be adapted to an ex isting panel cutout It is not required when the panel cutout size is as specified in the unit s data sheet 31 5 138 mm Three types of bezels are selectable when ordering Standard type Fits into M System s 48 Series panel cutout 38 139 5 mm Option D type Fits...

Page 3: ...nd below the unit for ventilation Bracket TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram on the side of the unit EXTERNAL DIMENSIONS unit mm inch 75 2 95 103 4 06 10 39 18 71 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 16 M3 SCREW TERMINALS 2 M3 SCREWS 144 5 67 137 5 5 41 4 1 16 36 1 42 31 1 22 100 3 94 Rounded corners for the option D OPTION D BEZEL 3 ...

Page 4: ...mm etc STANDARD BEZEL 2 10 4 41 7 5 30 3 9 15 136 5 5 37 144 5 67 11 4 45 7 5 30 4 9 19 136 5 5 37 144 5 67 8 5 33 10 4 41 7 5 30 136 5 5 37 144 5 67 OPTION F BEZEL 4 CONNECTION DIAGRAM 1 2 12 13 14 INPUT 15 16 7 8 9 ALARM OUTPUT CODE 2 2 points 1 2 INPUT 5 6 5 6 1 2 INPUT 5 6 15 16 ALARM OUTPUT CODE 0 None ALARM OUTPUT CODE 4 4 points 12 13 14 15 16 LLa 11 La LLb Lc LLc 8 9 10 HHa 7 Hc HHc HHb Ha...

Page 5: ...olor code 2 orange green green red red red H L 50 40 30 20 10 0 10 20 30 40 50 m3 h mA 100 SET H S P Z L 90 80 70 60 50 40 30 20 10 0 SET ENTER Button H Setpoint Adj Alarm Function Span Adj Setting Decimal Point Position Moving Average Brightness Adj Zero Adj Setting L Setpoint Adj Alarm Function Setting UP Button Switcing Detailed Settings Mode Setting Selector Setting DOWN Button Switcing Detail...

Page 6: ...ay for L Setpoint Increase Decrease Complete Digital Indicator SET L LL M Press at once ON Time Delay for LL Setpoint Increase Decrease Complete Digital Indicator SET LL Z M Press at once Zero Adjustment Digital Indicator Bargraph Z SET Z M Increase Decrease Zero Adjustment Digital Indicator Only Complete Z ON LED OFF SPAN ADJUSTMENT Apply 100 input signal before adjustment All alarm setpoints wil...

Page 7: ... is set to 7 the brightest level 3 Keep pressing DOWN button at least for 5 seconds to enter the simulated output mode 4 Pressing UP or DOWN button simulates the output between 000 0 and 100 0 5 Keep pressing SET button at least for 5 seconds to exit the simulated output mode Note Each setting sequence is complete only when SET button is pressed Once set parameters are not lost even after the powe...

Page 8: ...before H as the H setpoint can not go above the HH setpoint How to Cancel LL and L Alarms 1 Press UP or DOWN buttons until the indicator comes to the lower limit digital indicator shows and press SET LL indicator must be set before L as the L setpoint can not go below the LL setpoint LL or L H HH 1 2 ALARM ON TIME DELAY 1 Hold down M for 3 seconds 1 and push M to choose LL 2 Press UP and DOWN butt...

Page 9: ...vel Turn the power supply on and warm up for more than 10 minutes 1 ZERO Apply 0 input and adjust the bargraph digital indicator and DC output to 0 following the each proce dure explained in ADJUSTMENT PROCEDURE 2 SPAN Apply 100 input and adjust the bargraph digi tal indicator and DC output to 100 following the same procedure 3 Check ZERO adjustment again with 0 input 4 When ZERO value is changed ...