background image

JPS3

P.  / 5

EM-575 Rev.

PULSE ADDER

(field-programmable)

MODEL

JPS3

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Signal conditioner (body + base socket) ...................... (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.
When you need to change software settings, please refer to 
the Operation Manual for Model PU-2x (EM-9255), Section 
B.
This unit is factory adjusted and calibrated according to the 
Ordering Information included in the product package.  If 
you don’t need to change the pre-adjusted setting, you can 
skip the sections on hardware setting and calibration in this 
manual and the Operation Manual for Model PU-2x.

POINTS OF CAUTION

 POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

  85 – 132V AC rating: 85 – 132V, 47 – 66 Hz, approx. 6VA
  12V, 24V and 48V DC rating: Rating ±10%, approx. 3.3W
  110V DC rating: 85 – 150V, approx. 3.3W

 UNPLUGGING THE UNIT

• Before you remove the unit from its base socket or mount 

it, turn off the power supply and input signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +60°C     

(23 to 140°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close  to  noise  sources  (relay  drive  cable,  high  frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying  complete  performance  described  in  the  data 
sheet.

COMPONENT IDENTIFICATION

 FRONT PANEL CONFIGURATION

 HOW TO OPEN THE FRONT COVER

Position  your  finger  on  the  hook  at  the  top  of  front  cover 
and pull.

INSTALLATION

Detach the yellow clamps located at the top and bottom of 
the unit to separate the body from the base socket.

 DIN RAIL MOUNTING

Set the base socket so that its 
DIN rail adaptor is at the bot-
tom.  Position the upper hook 
at the rear side of base socket 
on the DIN rail and push in 
the  lower.    When  removing 
the  socket,  push  down  the 
DIN  rail  adaptor  utilizing  a 
minus screwdriver and pull.

 WALL MOUNTING

Refer  to  “EXTERNAL  DI-
MENSIONS.”

Body

Base Socket

Connection Diagram

Front Cover

Specifications

The shape of base socket may be different

for some models. 

Clamp

(top & bottom)

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

Shape and size of the base socket 

are slightly different with various 

socket types.

5

4

3

2

1

0

9 8 7 6

1

2

3

4

5

6

7

8
1

2

3

4

5

6

7

8

Output Voltage Adj.

Unused
Unused
Unused

One-shot Pulse

Width Adj.

Input Type Selectors

Input Monitor LED (PL2)

Modular Jack

Output Monitor LED

Input Monitor LED (PL1)

The JPS3 is programmed and calibrated at the factory according to 

the Ordering Information Sheet.

Please refer to the instruction manual for the model under “Software

Setting” when you need to modify certain specifications.

DO NOT change setting of unused switches and potentiometers.

Reviews: