background image

LTCNE

P.  / 2

EM-3352 Rev.

AC CURRENT TRANSDUCER

(self-powered)

MODEL

LTCNE

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Signal conditioner ......................................................... (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.

POINTS OF CAUTION

 GENERAL PRECAUTIONS

• Before you remove or mount the unit, turn off the input 

signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C     

(14 to 131°F) with relative humidity within 30 to 85% RH 
in order to ensure adequate life span and operation.

 WIRING

• Do  not  install  cables  (input  and  output)  close  to  noise 

sources (relay drive cable, high frequency line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

• The unit is designed to function as soon as the input sig-

nal is supplied, however, a warm up for 10 minutes is re-
quired  for  satisfying  complete  performance  described  in 
the data sheet.

COMPONENT IDENTIFICATION

INSTALLATION

 DIN RAIL MOUNTING

Set the unit so that its DIN rail adaptor is at the bottom.  
Position the upper hook at the rear side of the unit on the 
DIN rail and push in the lower.  When removing the unit, 
push  down  the  DIN  rail  adaptor  utilizing  a  minus  screw-
driver and pull.

 WALL MOUNTING

Refer to “EXTERNAL DIMENSIONS.”

Connection
Diagram

Span Adjustment

Body

Specifications

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

mailbox@sentronic.com

www.sentronic.com