R7G-SC-SHL
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7817-A Rev.2 P. 3 / 7
■
OPERATING MODE
• HLS transfer rate (SW1-1)
HLS TRANSFER RATE
CH1, CH2
SW1-1
12Mbps (*)
12M
6Mbps
6M
• HLS output at the loss of communication (SW1-2, 1-3)
HLS OUTPUT AT THE LOSS OF
COMMUNICATION
CH1
CH2
SW1-2
SW1-3
Hold the output (*)
(maintains the last data received
normally)
H1
H2
Reset the output (turned off)
C1
C2
• CC-Link output at the loss of communication (SW1-4)
CC-Link OUTPUT AT THE LOSS
OF COMMUNICATION
CH1, CH2
SW1-4
Hold the output (*)
(maintains the last data received
normally)
H
Reset the output (turned off)
C
(*) Factory setting
■
CC-Link BAUD RATE
Baud Rate is selected with the rotary switch.
5
4
3
2
1
0
9
8
7
6
Baud Rate Setting
0 : 156 kbps
1 : 625 kbps
2 : 2.5 Mbps
3 : 5 Mbps
4 : 10 Mbps
■
TERMINATING RESISTOR
To use the terminating resistor, turn the switch ON, and
OFF to invalidate. (Factory setting OFF)