background image

R8-DC4C

P. 4 / 4

EM-9743 Rev.1

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN

Phone: +81(6)6659-8201   Fax: +81(6)6659-8510   E-mail: info@m-system.co.jp

EXTERNAL DIMENSIONS

  unit: mm (inch)

115 (4.53)

6 (.24)

7 (.28)

6 (.24)

7 (.28)

DIN RAIL
(35 mm wide)

[3 (.12)]

[4 (.16)]

12 (.47)

59 (2.32)

55 (2.17)

CONNECTION DIAGRAM

NC

NC

1

2

4

3

NC

NC

1

2

4

3

OUTPUT 
CONNECTOR 1

OUTPUT
CONNECTOR 4

INTERNAL

BUS 

EXC.

SUPPLY

BUS CONNECTOR

INTERNAL

POWER 

*

1

*

1. Not used.

Do4

Do1

WIRING INSTRUCTIONS

 e-CON connector

connector XN2D-1474-S002 (Omron)
Recommended cable connector XN2A-1470 (Omron) *

1

Applicable wire size: 0.08 mm

2

 (AWG28) - 0.5 mm

2

 (AWG20)

Outer sheath diameter: max. 1.5 dia

*1.  The cable connector is not included in the package. 

 

Refer to the specifications of the product. 

Summary of Contents for R8-DC4C

Page 1: ...ty GENERAL PRECAUTIONS Before you remove or mount the unit turn off the power supply and output signal for safety Switches on the side of the module can be set for mainte nance only while the power supply is off Do not access them while the power is supplied ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air install the unit inside proper housing with sufficient ven t...

Page 2: ...ernal communication bus connector 2 I O modules cannot hold tightly on the DIN rail by themselves without power network module Secure them to the position if necessary by using DIN rail end plates Removing an intermediate module Protective Cover The protective cover is to be attached over the connected I O module at the right end Align the hooks on the cover with the grooves of the module and slid...

Page 3: ...OR The following parameters can be set with using PC Configu rator Software model R8CFG Output at the startup Output at the loss of communication Common setting loss of internal bus communication de tection time Turn SW4 8 ON to allow programming by the PC Configu rator via the Power Network Module Refer to the users manual for the R8CFG for detailed opera tion of the software program MODULE ADDRE...

Page 4: ...5 2 17 CONNECTION DIAGRAM NC NC 1 2 4 3 NC NC 1 2 4 3 OUTPUT CONNECTOR 1 OUTPUT CONNECTOR 4 INTERNAL BUS EXC SUPPLY BUS CONNECTOR INTERNAL POWER 1 1 Not used Do4 Do1 WIRING INSTRUCTIONS e CON connector connector XN2D 1474 S002 Omron Recommended cable connector XN2A 1470 Omron 1 Applicable wire size 0 08 mm2 AWG28 0 5 mm2 AWG20 Outer sheath diameter max 1 5 dia 1 The cable connector is not included...

Reviews: