background image

RPPD

5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201  Fax: +81(6)6659-8510  E-mail: info@m-system.co.jp

EM-1693  Rev.11  P. 2 / 7

COMPONENT IDENTIFICATION

Body

Base Socket

Connection Diagram

Front Cover

Specifications

 

HOW TO OPEN THE FRONT COVER:

Position your finger on the hook at the top of front cover 
and pull.

The shape of base socket may be different
for some models. 

 

FRONT PANEL CONFIGURATION

Front Cover (open)

Input Monitor LED PL2

Input Monitor LED PL1

INSTALLATION

Detach the yellow clamps located at the top and bottom of 
the unit for separate the body from the base socket.

 

DIN RAIL MOUNTING

Set the base socket so that its 
DIN rail adaptor is at the bot-
tom.  Position the upper hook 
at the rear side of base socket 
on the DIN rail and push in 
the lower.  When removing the 
socket, push down the DIN 
rail adaptor utilizing a minus 
screwdriver and pull.

 

WALL MOUNTING

Refer to “EXTERNAL DI-
MENSIONS.”

Clamp

(top & bottom)

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

Shape and size of the base socket 
are slightly different with various 
socket types.

Summary of Contents for RPPD

Page 1: ...ments in regard to the whole system and employ additional protective measures to ensure the CE conform ity Install lightning surge protectors for those wires connect ed to remote locations For 24V DC...

Page 2: ...nput Monitor LED PL2 Input Monitor LED PL1 INSTALLATION Detach the yellow clamps located at the top and bottom of the unit for separate the body from the base socket DIN RAIL MOUNTING Set the base soc...

Page 3: ...2 9 6 5 SENSOR EXC OUTPUT 1 1 2 U V POWER 7 8 3 4 5 6 OUTPUT 2 10 11 ROTARY ENCODER Input Connection Examples Open Collector Output Connection Examples Voltage Pulse Power Photo MOSFET Relay AC Power...

Page 4: ...I O PULSE LOGIC VOLTAGE PULSE or RS 422 LINE DRIVER PULSE OUTPUT WAVEFORM OPEN COLLECTOR or POWER PHOTO MOSFET RELAY The pulse width in one shot means the bold lined section of a pulse waveform Pulse...

Page 5: ...ON ON or OFF according to the adjustment 5 Noise filter Type 1 ON with OFF without ON or OFF according to the noise level Refer to the tables below for the max frequency which can pass through the fil...

Page 6: ...SW1 2 5 or SW1 2 6 3 Connect the positive probe to the test hole No 2 and turn the VH potentiometer until the meter shows desired val ue 1 4 Connect the positive probe to the test hole No 3 and turn t...

Page 7: ...mitter may fail 25 5 12 24 60 120 CURRENT mA VOLTAGE V Voltage V Current A 600mW MAINTENANCE TROUBLESHOOTING Refer to the flow chart below Checking Maintenance To TERMINAL CONNECTIONS End of Checking...