background image

F40PH Diesel Operating Manual

18

dings (signifying that the ProtoCoupler option has been turned off). Simply turn the
transformer throttle off and then on again to lock in the new setting.

PROGRAMMING FOR SQUEAKING BRAKES AND FYS
OPERATION

ProtoSounds™ is equipped with a RESET setting to turn off the Squeaking Brakes and

Passenger Station Proto-Effects (PFA) features. This is especially useful if you are double-
heading engines that are both equipped with PFA. You may not want to stop at a yard and
have both engines playing their PFA sound effects. To turn off PFA , enter RESET and go
to Feature 28. (See the section on Using RESET To Program ProtoSounds™ on page
15). Once in Feature 28, press the transformer whistle button and wait for ProtoSounds to
sound a bell ding(s). Continue pressing the whistle button on and off until ProtoSounds
sounds two bell dings (signifying that the PFA features have been turned off). Simply turn
the transformer throttle OFF and then ON again to lock in the new setting. To reset
ProtoSounds™ to its original factory setting of Squeaking Brakes and PFA on, repeat the
above procedure but keep pressing the whistle button in Feature 28 until ProtoSounds™
only dings once instead of twice.

ACTIVATING REMOTE LOCK-OUT CONTROL

ProtoSound equipped engines feature a RESET setting that allows the operator to

remotely “lock” the engine into forward, neutral or reverse. This is especially useful on
layouts that feature “blocked” track sections. The lockout feature comes from the factory in
the OFF position, meaning it is not active when you first take the engine out of the box. This
is done to prevent novice operators from accidentally locking their engine into forward,
neutral or reverse and then mistakenly thinking that the engine’s electronics have failed. To
activate the Remote Lockout Control setting, go to RESET Feature 40 (See the section
entitled Using RESET To Program ProtoSounds™ on page 15). Once in Feature 40,
press the transformer whistle button and wait for ProtoSounds to sound a bell ding.
Continue pressing the whistle button until ProtoSounds sounds two bell dings signifying
that the Remote Lockout Control has been selected. To lock in the setting, simply turn the
throttle all the way off and then back on again. To turn the Remote Lockout Control setting
back off, go back to Feature 40 and press the whistle button until only one bell ding sounds.
To lock in the setting, simply turn the transformer throttle off and then back on again.
Alternatively, you can go to RESET Feature 18 to reset all ProtoSound features back to
their original factory defaults including Remote Lockout Control.

RESETTING ALL PROTOSOUND OPTIONS TO FACTORY
DEFAULTS

ProtoSounds is equipped with a RESET feature (Feature 18) that resets all programmable

options back to their original factory settings. This is a useful feature if you find your engine
not operating the way you think it should and don’t want to take the time to check each
RESET feature one at a time. To reset all the RESET features back to their original factory
settings, enter RESET and go to Feature 18. (See the section entitled Using RESET To

Summary of Contents for EMD F40PH DIESELLOCOMOTIVE

Page 1: ...ng stock and accessories If you purchased the 2 rail model the engine should negotiate 36 inch radius curves and is completely compatible with any DC power source The locomotive is equipped with sever...

Page 2: ...ING THE ENGINE VOLUME 15 PROGRAMMING FOR A SEPARATE BELL BUTTON CONTROLLER 16 PROGRAMMING FOR SQUEAKING BRAKE OPERATION 16 PROGRAMMING FOR HORN IN NEUTRAL OPERATION 17 TURNING OFF CAB CHATTER SOUNDS 1...

Page 3: ...former direction switch if so equipped The 2 rail model s direction is controlled through the polarity of the DC power source and operate the same as all 2 rail DC engines The reverse unit is designed...

Page 4: ...If you don t choose to add the fluid then the smoke unit switch should be turned off Failure to either add the fluid or turn the switch off could lead to damage to the smoke unit heating element and...

Page 5: ...ble at most hobby shops Replacement smoke unit wicks can be purchased directly from MTH Electric Trains PROTOSOUNDS OPERATING INSTRUCTIONS The MTH ProtoSound digital sound and train control system pro...

Page 6: ...o determine if the system transformer and engine are operating correctly This takes approximately 2 2 seconds during which you will hear the engine s startup sounds begin In order for ProtoSounds to p...

Page 7: ...EUTRAL The bell will never ring continuously in RESET Remember NEUTRAL is the state between Forward and Reverse Once the bell is turned on it will continue to ring when the engine is cycled into forwa...

Page 8: ...nsformer throttle to enter either forward or reverse to allow the engine to begin running Note the brake sound will only be activated in the first direction state you enter after triggering the featur...

Page 9: ...once your engine comes to a stop or that the sounds stop prematurely before the engine comes to a complete halt For example if you simply run the engine and turn the throttle off quickly the brake sou...

Page 10: ...gine and put it into neutral If the throttle setting was at 14 volts or higher ProtoSounds will play the sound of squealing brakes as the engine comes to a stop I Upon stopping of the engine the opera...

Page 11: ...e Aboard and Tickets Please In addition to the two conductor highlights the station ambient sounds continue and still include passenger footsteps muffled voices baggage being moved about crashing soun...

Page 12: ...ith ProtoSounds or PFA If the engine isn t equipped with PFA the only thing to remember is that you not turn up the transformer throttle very high when entering the reverse state found in Event 3 If t...

Page 13: ...g the coupler If the coupler continues to open erratically try lubricating the knuckle with light oil as indicated in Fig 5 For multiple heading purposes only one of the two Proto Couplers will functi...

Page 14: ...while you wait for your replacement ProtoSound battery to arrive REPLACING THE PROTOSOUND BATTERY If you notice that the sounds seem distorted or garbled at low voltages or become silent when power fr...

Page 15: ...nd you will hear three clinks for Feature 3 Advance it two more times and you will hear a clank indicating that you are now in Feature 5 Advance the throttle two more times and you will hear a clank a...

Page 16: ...rogrammed for a bell button Simply turn the throttle off and then on again to Lock In the new setting To reset the computer to its original factory default setting no separate bell button operation re...

Page 17: ...eliminate repetitive and boring messages While the sounds are selected to play randomly by the unit s computer there is no guarantee that you won t hear the same message repeated twice or more times I...

Page 18: ...lockout feature comes from the factory in the OFF position meaning it is not active when you first take the engine out of the box This is done to prevent novice operators from accidentally locking th...

Page 19: ...PRESS THE WHISTLE BUTTON WHILE THE HORN IS BLOWING TURN THE THROTTLE OFF AND THEN LET GO OF THE WHISTLE BUTTON After three seconds without power you will hear one chime of the RESET bell TURN ON THE P...

Page 20: ...located on each end of the chassis as seen in Fig 8 above After removing the screws lift the body away from the chassis and lay the body next to the chassis Next remove the truck blocks from the chas...

Page 21: ...wdriver pry away any remains left from the old tire that may still be in the drive wheel groove Once the old tire has been completely removed slip the new tire onto the wheel You may find it useful to...

Page 22: ...e power twice to enter Neutral set the voltage at 8 volts or less and press the whistle button to activate the bell I can t get the bell to ring when I press the whistle button You may be pressing the...

Page 23: ...olume level BATTERY PROBLEMS REMEDY I get no sounds when the engine shifts between the direction states The battery may be dead or needs charging See the Battery Backup section for more information Af...

Page 24: ...t to hear the passenger station sounds after entering neutral turn the power off for three seconds to disable the passenger station sound effects FYS PROBLEMS REMEDY The FYS feature does not begin eve...

Page 25: ...will play Transformer Type Outside Rail Center Rail Min Max Voltage Power Rating Lionel 1032 A U 5 16v 90 Watt Lionel 1032M A U 5 16v 90 Watt Lionel 1033 A U 5 16v 90 Watt Lionel 1043 A U 5 16v 90 Wa...

Page 26: ...er whistle button until you hear a soft warbled bell sound RESET OPERATION DEFAULT SETTING CLINKS CLANKS 6 Diesel Volume Full Volume 5 Clinks 1 Clank 10 Coupler On Off Coupler On 0 Clinks 2 Clanks 18...

Page 27: ...ter including your name address daytime phone number Return Authorization number and a full description of the problem must be included to facilitate the repairs Please include the description regardl...

Reviews: