background image

F40PH Diesel Operating Manual

8

SQUEAKING BRAKE SOUNDS

ProtoSounds is now equipped with operator controlled squeaking brake sounds. Once

activated, this easy to use feature plays the sound of squeaking brakes whenever the
transformer throttle is reduced from high voltage to low voltage simulating the application of
the brakes as you enter curves or slow down for crossings and passenger stations. The
sound itself is a stored record on the ProtoSounds software chip and will always play the
same brake sound for the same 3 second length each time you reduce the voltage from
high to low.

ACTIVATING AND TRIGGERING THE SQUEAKING BRAKE SOUNDS

Before the brake squeaking can be heard, ProtoSounds must be activated for the brake

sound feature. The brake sound feature can be activated in two ways.

Option 1:

If you are using a separate bell button controller to ring your bell (like the Lionel

Railsounds No. 5906 bell activation button) you can activate the squealing brake feature by
pressing and holding the bell button for three seconds or longer (it doesn’t matter if you are
in forward, neutral or reverse). You will hear the bell chiming turn on and if you listen
carefully you should hear an air release sound after three seconds have passed at which
time you can release the bell button. (

Note:

because the air release sound is hard to hear,

we recommend that you count out a full three seconds before releasing the bell button

.)

The bell will continue to chime, so if you want to turn off the bell ringing, simply press and
release the bell button a second time. If you were in neutral when you triggered the brake
feature, interrupt the transformer throttle to enter either forward or reverse to allow the
engine to begin running. (

Note:

the brake sound will only be activated in the first direction

state you enter after triggering the feature from the neutral position. You cannot interrupt

the power twice to enter another direction state and still have the brake feature active

.)

Once your engine begins running, you can activate the brake sounds by reducing the
transformer voltage from a high setting to a low setting.

Option 2

If you do not have a separate bell button on your layout, you can still activate the

brake sound feature with your transformer whistle button. To activate the brake feature turn
on the transformer throttle and get your engine into the neutral position (not RESET). Once
in neutral, set the transformer throttle at 8 volts or less and press and hold the whistle button
for at least three seconds. You will hear the bell chiming turn on and if you listen carefully
you should hear an air release sound after three seconds have passed at which time you
can release the whistle button. (

Note:

because the air release sound is hard to hear, we

recommend that you count out a full three seconds before releasing the whistle button.

)

The bell will continue to chime, so if you want to turn off the bell ringing, simply press and
release the bell button a second time. Interrupt the transformer throttle to enter either
forward or reverse to allow the engine to begin running. (

Note:

the brake sound will only be

activated in the first direction state you enter after triggering the feature from the neutral

position. You cannot interrupt the power twice to enter another direction state and still have

the brake feature active.

) Once your engine begins running, you can activate the brake

sounds by reducing the transformer voltage from a high setting to a low setting.

Summary of Contents for EMD F40PH DIESELLOCOMOTIVE

Page 1: ...ng stock and accessories If you purchased the 2 rail model the engine should negotiate 36 inch radius curves and is completely compatible with any DC power source The locomotive is equipped with sever...

Page 2: ...ING THE ENGINE VOLUME 15 PROGRAMMING FOR A SEPARATE BELL BUTTON CONTROLLER 16 PROGRAMMING FOR SQUEAKING BRAKE OPERATION 16 PROGRAMMING FOR HORN IN NEUTRAL OPERATION 17 TURNING OFF CAB CHATTER SOUNDS 1...

Page 3: ...former direction switch if so equipped The 2 rail model s direction is controlled through the polarity of the DC power source and operate the same as all 2 rail DC engines The reverse unit is designed...

Page 4: ...If you don t choose to add the fluid then the smoke unit switch should be turned off Failure to either add the fluid or turn the switch off could lead to damage to the smoke unit heating element and...

Page 5: ...ble at most hobby shops Replacement smoke unit wicks can be purchased directly from MTH Electric Trains PROTOSOUNDS OPERATING INSTRUCTIONS The MTH ProtoSound digital sound and train control system pro...

Page 6: ...o determine if the system transformer and engine are operating correctly This takes approximately 2 2 seconds during which you will hear the engine s startup sounds begin In order for ProtoSounds to p...

Page 7: ...EUTRAL The bell will never ring continuously in RESET Remember NEUTRAL is the state between Forward and Reverse Once the bell is turned on it will continue to ring when the engine is cycled into forwa...

Page 8: ...nsformer throttle to enter either forward or reverse to allow the engine to begin running Note the brake sound will only be activated in the first direction state you enter after triggering the featur...

Page 9: ...once your engine comes to a stop or that the sounds stop prematurely before the engine comes to a complete halt For example if you simply run the engine and turn the throttle off quickly the brake sou...

Page 10: ...gine and put it into neutral If the throttle setting was at 14 volts or higher ProtoSounds will play the sound of squealing brakes as the engine comes to a stop I Upon stopping of the engine the opera...

Page 11: ...e Aboard and Tickets Please In addition to the two conductor highlights the station ambient sounds continue and still include passenger footsteps muffled voices baggage being moved about crashing soun...

Page 12: ...ith ProtoSounds or PFA If the engine isn t equipped with PFA the only thing to remember is that you not turn up the transformer throttle very high when entering the reverse state found in Event 3 If t...

Page 13: ...g the coupler If the coupler continues to open erratically try lubricating the knuckle with light oil as indicated in Fig 5 For multiple heading purposes only one of the two Proto Couplers will functi...

Page 14: ...while you wait for your replacement ProtoSound battery to arrive REPLACING THE PROTOSOUND BATTERY If you notice that the sounds seem distorted or garbled at low voltages or become silent when power fr...

Page 15: ...nd you will hear three clinks for Feature 3 Advance it two more times and you will hear a clank indicating that you are now in Feature 5 Advance the throttle two more times and you will hear a clank a...

Page 16: ...rogrammed for a bell button Simply turn the throttle off and then on again to Lock In the new setting To reset the computer to its original factory default setting no separate bell button operation re...

Page 17: ...eliminate repetitive and boring messages While the sounds are selected to play randomly by the unit s computer there is no guarantee that you won t hear the same message repeated twice or more times I...

Page 18: ...lockout feature comes from the factory in the OFF position meaning it is not active when you first take the engine out of the box This is done to prevent novice operators from accidentally locking th...

Page 19: ...PRESS THE WHISTLE BUTTON WHILE THE HORN IS BLOWING TURN THE THROTTLE OFF AND THEN LET GO OF THE WHISTLE BUTTON After three seconds without power you will hear one chime of the RESET bell TURN ON THE P...

Page 20: ...located on each end of the chassis as seen in Fig 8 above After removing the screws lift the body away from the chassis and lay the body next to the chassis Next remove the truck blocks from the chas...

Page 21: ...wdriver pry away any remains left from the old tire that may still be in the drive wheel groove Once the old tire has been completely removed slip the new tire onto the wheel You may find it useful to...

Page 22: ...e power twice to enter Neutral set the voltage at 8 volts or less and press the whistle button to activate the bell I can t get the bell to ring when I press the whistle button You may be pressing the...

Page 23: ...olume level BATTERY PROBLEMS REMEDY I get no sounds when the engine shifts between the direction states The battery may be dead or needs charging See the Battery Backup section for more information Af...

Page 24: ...t to hear the passenger station sounds after entering neutral turn the power off for three seconds to disable the passenger station sound effects FYS PROBLEMS REMEDY The FYS feature does not begin eve...

Page 25: ...will play Transformer Type Outside Rail Center Rail Min Max Voltage Power Rating Lionel 1032 A U 5 16v 90 Watt Lionel 1032M A U 5 16v 90 Watt Lionel 1033 A U 5 16v 90 Watt Lionel 1043 A U 5 16v 90 Wa...

Page 26: ...er whistle button until you hear a soft warbled bell sound RESET OPERATION DEFAULT SETTING CLINKS CLANKS 6 Diesel Volume Full Volume 5 Clinks 1 Clank 10 Coupler On Off Coupler On 0 Clinks 2 Clanks 18...

Page 27: ...ter including your name address daytime phone number Return Authorization number and a full description of the problem must be included to facilitate the repairs Please include the description regardl...

Reviews: