Premier E33 

 Electric Engine

OPERATOR’S MANUAL

(3V PS-2)

Compatibility

This engine will operate on any 
traditional O-42 Gauge track system, 
including M.T.H.’s RealTrax® or 
ScaleTrax™ or traditional tubular 
track. It is also compatible with most 
standard AC transformers.  (See page 
19 for a complete list of  compatible 
transformers and wiring instructions.)

Freight Yard Sound

Passenger Station Announcement

PLEASE READ THIS MANUAL BEFORE USE AND SAVE

WWW.MTHTRAINS.COM

Summary of Contents for Premier E33 Electric Engine

Page 1: ...system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 19 for a complete list of compatible transformers and wir...

Page 2: ...Read this manual thoroughly before using this device l M T H recommends that all users and persons supervising use examine the hobby transformer and other electronic equipment periodically for condit...

Page 3: ...y a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeable battery has run down and needs to be charge...

Page 4: ...will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and release...

Page 5: ...e of all sounds made by this engine turn the manual volume control shown below clockwise to increase the volume and counter clockwise to decrease the volume Premier E33 Electric Engine with PS 2 5 Man...

Page 6: ...but firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each press Press the...

Page 7: ...evel once you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automaticall...

Page 8: ...l then quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repeat the 1 horn wh...

Page 9: ...blasts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing Brakes play any...

Page 10: ...gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first Remove the two grease port screws two per gearbox Use a gre...

Page 11: ...Maintenance Kit 30 50010 or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that you are using clean cloth on...

Page 12: ...ains 4 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over the wheel you...

Page 13: ...te the burned out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main harness wire Replacement bulb harnesses are available directly from the M T H Parts departm...

Page 14: ...to recharge the battery overnight without leaving it on the track Replace If the sounds are not improved at the end of the 15 minute test charge it is time to replace the battery Available through M T...

Page 15: ...bell button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled...

Page 16: ...d into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is set...

Page 17: ...as realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequences FYS...

Page 18: ...le button push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions includin...

Page 19: ...ard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Le...

Page 20: ...refully before returning any merchandise for service Authorized M T H Service Centers are independently owned and operated and are not agents or representatives of M T H Electric Trains M T H assumes...