Self  Charging Battery Back-up

The special NiCad 2.4v self-charging battery recharges continuously during train 
operation and should last for up to five years.  The battery is a dry battery that 
should not leak or cause any damage to your engine.  Depending upon when your 
engine was built, it may need to be charged right out of  the box.  If  engine sounds 
seem distorted or garbled at low voltages or become silent when power from the 
transformer is turned off, test the battery to determine whether it should be 
recharged or replaced.

Leave the engine in neutral with track voltage at 10-12 volts for 6-7 hours so 
the battery can fully recharge (if  your engine has a smoke unit, be sure it is 
turned off).  

Use M.T.H.'s battery recharger (Item No. 50-1019) (sold separately) that plugs 
into a wall outlet and a special port under the engine to recharge the battery 
overnight without leaving it on the track.

Replace:

  If  the sounds are not improved at the end of  the 15-minute test charge, 

it is time to replace the battery.  Available through M.T.H. Parts:
(Item No.  50-1024) AA NiCad Proto-Sound® Battery 

DO NOT substitute alkaline batteries for these NiCad batteries. Using alkaline 
batteries in this system can result in damamge to the PS 2.0 circuit board and/or 
the batteries.  

**Do not use alkaline batteries for testing or checking purposes for the 3-Volt PS2 
boards. Using alkaline batteries will damage the 3-Volt battery charging circuit.**    

Premier E33 Electric Engine with PS-2 

14

Test:

  Put the engine in neutral and leave 

the track voltage at 10-12 volts (high 
enough for the lights to shine brightly) for 
15 minutes.

Recharge:

  If  the sounds are improved at 

the end of  the 15-minute test charge, the 
battery charge has run down and can be 
recharged.  There are a number of  ways 
you can do this: 

Battery Charger Port

Battery Charger Port location.

Battery Location

Lift Out Battery

Summary of Contents for Premier E33 Electric Engine

Page 1: ...system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 19 for a complete list of compatible transformers and wir...

Page 2: ...Read this manual thoroughly before using this device l M T H recommends that all users and persons supervising use examine the hobby transformer and other electronic equipment periodically for condit...

Page 3: ...y a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeable battery has run down and needs to be charge...

Page 4: ...will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and release...

Page 5: ...e of all sounds made by this engine turn the manual volume control shown below clockwise to increase the volume and counter clockwise to decrease the volume Premier E33 Electric Engine with PS 2 5 Man...

Page 6: ...but firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each press Press the...

Page 7: ...evel once you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automaticall...

Page 8: ...l then quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repeat the 1 horn wh...

Page 9: ...blasts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing Brakes play any...

Page 10: ...gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first Remove the two grease port screws two per gearbox Use a gre...

Page 11: ...Maintenance Kit 30 50010 or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that you are using clean cloth on...

Page 12: ...ains 4 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over the wheel you...

Page 13: ...te the burned out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main harness wire Replacement bulb harnesses are available directly from the M T H Parts departm...

Page 14: ...to recharge the battery overnight without leaving it on the track Replace If the sounds are not improved at the end of the 15 minute test charge it is time to replace the battery Available through M T...

Page 15: ...bell button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled...

Page 16: ...d into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is set...

Page 17: ...as realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequences FYS...

Page 18: ...le button push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions includin...

Page 19: ...ard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Le...

Page 20: ...refully before returning any merchandise for service Authorized M T H Service Centers are independently owned and operated and are not agents or representatives of M T H Electric Trains M T H assumes...

Reviews: