Troubleshooting Proto-Sound® Problems

Although Proto-Sound 2.0 has been designed and engineered for ease of  use,
 you may have some questions during initial operation.  The following table
 should answer most questions.  If your problem cannot be resolved with this 
table, contact M.T.H. for assistance (www.mth-railking.com, e-mail: parts@mth-
railking.com,Fax:  410-423-0009, Phone: 410-381-2500, Mail: 7020 Columbia 
Gateway Drive, Columbia MD 21046-1532,

Premier E33 Electric Engine with PS-2 

15

Starting Up

Whistle/Horn

Bell

Coupler

Remedy

Remedy

Remedy

Remedy

Remedy

When I first turn the power on, the 
engine will not begin to run.  I 
have to turn the throttle off and 
then on again to get the engine to 
operate.

When I press the whistle/horn 
button, the bell comes on instead.

I can’t get the horn to blow when I 
press the whistle button.

I can’t get the bell to ring when I 
press the bell button.

The bell won’t work on a separate 
bell button.

When I try to fire the coupler, FYS 
starts.

The Proto-Coupler won’t let the 
engine uncouple on the fly.

The coupler does not fire or stay 
coupled.

When I press the whistle button, 
the bell sounds.

Reverse the transformer leads.

You may be pressing the button 
too quickly. Try pressing the 
whistle/horn button more slowly, 
taking approximately one full 
second to fully depress the button.

You may be pressing the button 
too quickly. Try pressing the bell 
button more slowly, taking 
approximately one full second to 
fully depress the button.

Reverse the transformer leads.

Check the wiring of the separate 
button.

You are waiting too long between 
whistle button presses.

Try lubricating the coupler knuckle 
with a dry graphite lubricant. Do 
NOT use oil.

The coupler needs to be cleaned.  
Wipe with denatured alcohol (not 
rubbing alcohol) and let dry.

This is normal behavior.  To 
prevent accidental high-speed 
start-ups, Proto-Sound 2.0 is 
programmed to start up in neutral 
anytime track power has been 
turned off for several seconds.  

Summary of Contents for Premier E33 Electric Engine

Page 1: ...system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 19 for a complete list of compatible transformers and wir...

Page 2: ...Read this manual thoroughly before using this device l M T H recommends that all users and persons supervising use examine the hobby transformer and other electronic equipment periodically for condit...

Page 3: ...y a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeable battery has run down and needs to be charge...

Page 4: ...will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and release...

Page 5: ...e of all sounds made by this engine turn the manual volume control shown below clockwise to increase the volume and counter clockwise to decrease the volume Premier E33 Electric Engine with PS 2 5 Man...

Page 6: ...but firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each press Press the...

Page 7: ...evel once you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automaticall...

Page 8: ...l then quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repeat the 1 horn wh...

Page 9: ...blasts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing Brakes play any...

Page 10: ...gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first Remove the two grease port screws two per gearbox Use a gre...

Page 11: ...Maintenance Kit 30 50010 or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that you are using clean cloth on...

Page 12: ...ains 4 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over the wheel you...

Page 13: ...te the burned out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main harness wire Replacement bulb harnesses are available directly from the M T H Parts departm...

Page 14: ...to recharge the battery overnight without leaving it on the track Replace If the sounds are not improved at the end of the 15 minute test charge it is time to replace the battery Available through M T...

Page 15: ...bell button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled...

Page 16: ...d into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is set...

Page 17: ...as realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequences FYS...

Page 18: ...le button push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions includin...

Page 19: ...ard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Le...

Page 20: ...refully before returning any merchandise for service Authorized M T H Service Centers are independently owned and operated and are not agents or representatives of M T H Electric Trains M T H assumes...

Reviews: