background image

Service & Warranty Information

How to Get Service Under the Terms of  the Limited One-Year Warranty

When you suspect an item is defective, please check the operator's manual for standard operation and trouble-
shooting techniques that may correct the problem.  Additional information may be found on the M.T.H. Website.  
Should you still require service, follow the instructions below to obtain warranty service.

First, e-mail, write, call or fax M.T.H. Electric Trains or  a M.T.H. Authorized Service Center (ASC) in your area 
to obtain Repair Authorization.  You can find the list of ASCs on the M.T.H. Website, www.mth-railking.com.  
Authorized Service Centers are required to make warranty repairs on items sold 

only

 from that store; all other 

repairs may-- or may not be done at the store's own discretion.  If you did not purchase the item directly from 
the ASC, you will need to select a National Authorized Service Center (NASC) or contact M.T.H. Electric Trains 
directly. NASC Dealers are compensated by M.T.H. to perform warranty service for any customer whose repair 
qualifies for warranty service.  A list of  NASC retailers can be located on the M.T.H. Website or by calling 410-
381-2580.  Should the warranty no longer apply, you may choose either an ASC or NASC retailer to service your 
M.T.H. Product.  A reasonable service fee will be charged.

CAUTION:  Make sure the product is packed in its original factory packaging including its foam and plastic 
wrapping material to prevent damage to the merchandise.  There is no need to return the entire set if only one 
of  the components is in need of  repair 

unless otherwise instructed by the Service Center

.  

The shipment must be 

prepaid and we recommend that it be insured. A cover letter including your name, address, daytime 
phone number, e-mail address (if  available), Return Authorization number (if  required by the service 
center, a copy of your sales receipt and a full description of  the problem must be included to facilitate 
the repairs.  Please include the description regardless of  whether you discussed the problem with a 
service technician when contacting the Service Center for your Return Authorization.

Please make sure you have followed the instructions carefully before returning any merchandise for service.  
Authorized M.T.H. Service Centers are independently owned and operated and are not agents or representatives 
of  M.T.H. Electric Trains.  M.T.H. assumes no responsibility, financial or otherwise, for material left in their 
possession, or work done, by privately owned M.T.H. Authorized Service Centers.
If  you need assistance at any time email MTH Service at service@mth-railking.com, or call 410 381-2580.

Limited One-Year Warranty

All M.T.H. products purchased from an Authorized M.T.H. Retailer are covered by this warranty.                        
See our Website to identify an Authorized M.T.H. Retailer near you. 

M.T.H. products are warrantied for one year from the date of purchase against defects in material or 
workmanship, excluding wear items such as light bulbs, pick-up rollers, batteries, smoke unit wicks, and traction 
tires. We will replace or credit (at our option) any defective item with a manufactured suggested retail price of 
$279.95 or less (excluding all motive power and electronic items), if the item is returned to an M.T.H. Authorized 
Service Center (ASC) or M.T.H. National Authorized Service Center (NASC) within one year of the original date 
of  purchase.  For any item with an MSRP greater than $279.95 (including all motive power and electronics), We 
will repair, replace or credit (at our option) the defective item without charge for the parts or labor, if the item is 
returned to an M.T.H. Authorized Service Center (ASC) or M.T.H. National Authorized Service Center (NASC) 
within one year of  the original date of  purchase. This warranty does not cover damages caused by improper care, 
handling, or use. Transportation costs incurred by the customer to ship the product for warranty service are not 
covered under this warranty. 

Items sent for repair must be accompanied by a return authorization number, a description of the problem, and 
a copy of  the original sales receipt from an Authorized M.T.H. Retailer stating the date of purchase. If  you are 
sending this product to an Authorized Service Center, contact that Center for their return authorization. 

This warranty gives you specific legal rights, and you may have other rights that vary from state to state. Specific 
questions regarding the warranty may be forwarded to M.T.H. directly. 

Service Department
M.T.H. Electric Trains
7020 Columbia Gateway Drive
Columbia MD 21046-1532
410-381-2580
service@mth-railking.com

Summary of Contents for Premier E33 Electric Engine

Page 1: ...system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See page 19 for a complete list of compatible transformers and wir...

Page 2: ...Read this manual thoroughly before using this device l M T H recommends that all users and persons supervising use examine the hobby transformer and other electronic equipment periodically for condit...

Page 3: ...y a drop or two on each pivot point Checking the Battery You may find if your locomotive was built several months before you set it up that the rechargeable battery has run down and needs to be charge...

Page 4: ...will maintain the speed you set after you release the throttle until you turn it again to change the voltage and speed Bell To sound the bell in an engine equipped with a bell firmly press and release...

Page 5: ...e of all sounds made by this engine turn the manual volume control shown below clockwise to increase the volume and counter clockwise to decrease the volume Premier E33 Electric Engine with PS 2 5 Man...

Page 6: ...but firmly tap the Bell button once followed by 2 quick taps of the Horn Whistle button while the engine is moving Tap the buttons quickly but allow approximately second between each press Press the...

Page 7: ...evel once you have stopped the engine to run the FYS PSA Otherwise the engine without FYS PSA will begin vibrating on the track as its motors strain to move the train since they cannot be automaticall...

Page 8: ...l then quickly tap the transformer s horn whistle button one time then quickly tap the Bell button two times allowing approximately second to lapse between each quick button press Repeat the 1 horn wh...

Page 9: ...blasts will indicate that the engine has made the change Automatic Sounds Certain Proto Sound 2 0 sound effects automatically play in programmed conventional mode conditions Squealing Brakes play any...

Page 10: ...gearing was greased at the factory and should not need additional grease until after 50 hours of operation or one year whichever comes first Remove the two grease port screws two per gearbox Use a gre...

Page 11: ...Maintenance Kit 30 50010 or denatured not rubbing alcohol and a clean rag Unplug the transformer and wipe the rails of the track turning the rag frequently to ensure that you are using clean cloth on...

Page 12: ...ains 4 Slip the new tire onto the wheel You may find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over the wheel you...

Page 13: ...te the burned out light bulb s Carefully remove bulb s from mounting Disconnect light bulb harness from main harness wire Replacement bulb harnesses are available directly from the M T H Parts departm...

Page 14: ...to recharge the battery overnight without leaving it on the track Replace If the sounds are not improved at the end of the 15 minute test charge it is time to replace the battery Available through M T...

Page 15: ...bell button The bell won t work on a separate bell button When I try to fire the coupler FYS starts The Proto Coupler won t let the engine uncouple on the fly The coupler does not fire or stay coupled...

Page 16: ...d into the neutral position Follow the procedure in the Lock into a Direction section Engine speed must be below 10 scale mph approx 10 volts or less in conventional mode Proto Sound 2 0 volume is set...

Page 17: ...as realistic as possible Proto Sound 2 0 disables the reversing unit whenever FYS PSA is enabled This way the engine remains still at its stop as the operator cycles through the FYS PSAsequences FYS...

Page 18: ...le button push stops all Proto Sound 2 0 trains but does not turn off the power One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives user defined actions includin...

Page 19: ...ard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Hostler Le...

Page 20: ...refully before returning any merchandise for service Authorized M T H Service Centers are independently owned and operated and are not agents or representatives of M T H Electric Trains M T H assumes...

Reviews: