Warranty 

 

M-Tec A/S products are covered by a limited manufacturer warranty. The M-tec A/S 
warranty is limited to the warranty rules and legislation present in each country. The 
warranty only covers manufacturing faults.  
 
The warranty does not cover misuse, wrong installation or damage due to a faulty 
installation or wrong maintenance. 
 
The invoice act as the proof of warranty, so please keep it as reference for any warranty 
complaints. 
 
 

Technical Assistance 

 
If you have a problem and cannot find the information you need in the product 
documentation, please contact M-Tec A/S  
 
 
M-Tec A/S 
Industrivej 10 
9490 Pandrup 
Tel: +45 99 73 00 20 
Fax: +45 96 73 74 07 

E-mail:

 

support@m-tec.dk

  

http://www.m-tec.dk/en/

 

www.trackunit.com

  

 

 
 
 

 
 
 
 

 
When contacting technical support, please be prepared to provide the information listed 
below: 
 

Minimum Information Required for Technical Assistance 

 
If you or a user reports difficulty with a ME401 unit (i.e. no GPS fixes, not communicating, 
LED not working, etc.), it is helpful to retrieve directly from the unit all current configuration 
settings and the message log data etc, that is accessible by the technical support when 
they receive the following information about the unit. 
 
1. Unit Serial number 

Summary of Contents for ME 401-2

Page 1: ...ME401 2 Technical Manual Version 1 3a September 2012...

Page 2: ...Motion sensor 11 1 Wire input 11 Installation of the ME401 2 in machinery 12 Installation of the ME401 2 in vehicles 13 Functionality check 14 LED 14 Status SMS Commands 14 Installation of the digital...

Page 3: ...s standard return material authorization procedures or as otherwise instructed by M Tec Warranty Exclusions and Disclaimers The foregoing Product Limited Warranty shall only apply in the event and to...

Page 4: ...rference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfer...

Page 5: ...portable document format PDF from the following web site www trackunit com Alternatively the latest version of this manual can also be downloaded from the factory website http www m tec dk Related In...

Page 6: ...esistant according to the IP 67 standard It is however recommended that it is be used where it is relatively dry and not subjected to either water streams or submersion Recycling For information on ho...

Page 7: ...llation so any vehicle moving machinery construction machinery installed with the ME401 etc must not enter any facility where posted notices prohibit the use of wireless phones or two way radios Aircr...

Page 8: ...between the ME401 and any persons body Additional information on Specific Absorption Rates SAR can be found on the Cellular Telecommunications Internet Association CTIA Web site at www ctia org Batter...

Page 9: ...horized GSM network is available While a basic understanding of the different ME401 2 operational states is helpful configuring the ME401 2 unit does not require a highly skilled software programmer o...

Page 10: ...the unit make sure it is only mounted beneath plastic parts or similar parts wood but not beneath metal parts To reduce hum and noise in the FM radio it is recommended to place the unit at a minimum d...

Page 11: ...its overload and is also protected against over voltage For further information about connection possibilities of the digital output see chapters about installation later in this manual Motion sensor...

Page 12: ...ected to a ID06 Card reader Min 8V DC voltage at input 5 Pink Digital input 4 Can be connected to an external sensor for detecting a critical running mode or an alarm Min 8V DC voltage at input 6 Gree...

Page 13: ...ly through a 1 amp fuse 2 White Digital input 1 Connect to the operating hours counter Min 8V DC voltage at the input 3 Brown Digital input 2 Connect to the ignition signal Min 8V DC voltage at the in...

Page 14: ...interrupted by a red blink The unit is attached to the GSM network and the GPS is navigating Everything is OK No light The unit is not connected to a power supply Constant red light The unit is power...

Page 15: ...ngs garage would reduce signal quality MT SIGNAL MTC ACK SERIAL No SIGNAL GSM 22 SAT 8 SN 44 GSM is a measure for the quality of the GSM coverage The value should be at least 10 Maximum value for GSM...

Page 16: ...he unit is off thus no power on the unit Check if the installation is performed correctly according to the guidelines of this manual F3 The LED is constant red thus the unit is not attached to the GSM...

Page 17: ...supply voltage The current consumption of the relay must not exceed 200 mA DC current and the relay contacts must be specified to withstand the load that needs to be controlled NOTE The output can onl...

Page 18: ...UT1 ON With this command the output is activated permanently The output can be de activated again using the OFF command Deactivation of the output MT OUT1 OFF MTC ACK SERIAL No OUT1 OFF With this comm...

Page 19: ...problem and cannot find the information you need in the product documentation please contact M Tec A S M Tec A S Industrivej 10 9490 Pandrup Tel 45 99 73 00 20 Fax 45 96 73 74 07 E mail support m tec...

Page 20: ...product plus return freight costs will be issued not taken into consideration the original purchase costs Try to make the error description as detailed as possible Insufficient error descriptions will...

Page 21: ...installation Charging time for an empty backup battery 3 hours at 25 C Expected lifetime of the backup battery 3 years Digital inputs Up to 6 Digital outputs Up to 2 Temperature range In active runnin...

Page 22: ...tomotive Directive 2004 104 EEC UN regulative ECE R10 EMC rev 3 The ME401 product complies with the essential requirements of the Directive 2003 37 EEC and Directive 2006 42 EEC The ME401 product comp...

Page 23: ...for equipment on rolling stock CE The ME401 product complies with the essential requirements of the R TTE Directive 1999 5 EC as stated by the EC Declaration of Conformity Certificates and Declaration...

Reviews: