  It is recommended that a minimum separation of ten (8”) inches (20 cm) is to be 

maintained between the ME401 unit and any persons’ body at all times. The device 
is SAR tested and approved for a separation distance of only (2") inches (5 cm) 
between the ME401 and any person’s body. 

  Do not carry the ME401 on your person. 

 

Other Medical Devices 

If any other personal medical devices are used in the vicinity of a ME401 unit, consult the 
manufacturers of the medical devices to determine if they are adequately shielded from 
external RF energy. Physicians may be able to assist in obtaining this information. 
 
The ME401 unit cannot be turned off after installation, so any vehicle, moving machinery, 
construction machinery installed with the ME401 etc. must not operate near health care 
facilities when any regulations posted in these areas prohibit the use of wireless phones or 
two-way radios. Hospitals and health care facilities may be using equipment that could be 
sensitive to external RF energy. 
 

Vehicles 

RF signals may affect improperly installed or inadequately shielded electronic systems in 
motor vehicles. Check with the manufacturer or its representative regarding the vehicle. 
Also consult the manufacturer of any equipment that has been added to the vehicle. 
 

Posted Facilities 

The ME401 unit cannot be turned off after installation, so any vehicle, moving machinery, 
construction machinery installed with the ME401 etc. must not enter any facility where 
posted notices prohibit the use of wireless phones or two-way radios. 
 

Aircrafts 

FCC and FAA regulations prohibit using wireless phones while in the air. Do not carry the 
ME401 unit aboard an aircraft as it cannot be turned off. 

 

The ME401 unit cannot be turned off after installation, so any vehicle, moving machinery, 
construction machinery installed with the ME401 etc. must not enter a “blasting area” or in 
areas posted “turn off two way radio” to avoid interfering with blasting operations. Obey all 
signs and instructions. 
 

Potentially Explosive Atmospheres 

The ME401 unit cannot be turned off after installation, so any vehicle, moving machinery, 
construction machinery installed with ME401 etc. must not enter any area with a potentially 
explosive atmosphere and obey all signs and instructions. Sparks in such areas could 
cause an explosion or fire resulting in bodily injury or even death. 
 
Areas with a potentially explosive atmosphere are often, but not always marked clearly. 
Potential areas may include: fueling areas (such as gasoline stations); below deck on 
boats; fuel or chemical transfer or storage facilities; vehicles using liquefied petroleum gas 
(such as propane or butane); areas where the air contains chemicals or particles (such as 
grain, dust, or metal powders); and any other area where it would normally be advisable to 
turn off motor vehicle engines it is not allowed to enter with a vehicle, moving machinery, 
construction machinery installed with the ME401. 
 
 

Summary of Contents for ME 401-2

Page 1: ...ME401 2 Technical Manual Version 1 3a September 2012...

Page 2: ...Motion sensor 11 1 Wire input 11 Installation of the ME401 2 in machinery 12 Installation of the ME401 2 in vehicles 13 Functionality check 14 LED 14 Status SMS Commands 14 Installation of the digital...

Page 3: ...s standard return material authorization procedures or as otherwise instructed by M Tec Warranty Exclusions and Disclaimers The foregoing Product Limited Warranty shall only apply in the event and to...

Page 4: ...rference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfer...

Page 5: ...portable document format PDF from the following web site www trackunit com Alternatively the latest version of this manual can also be downloaded from the factory website http www m tec dk Related In...

Page 6: ...esistant according to the IP 67 standard It is however recommended that it is be used where it is relatively dry and not subjected to either water streams or submersion Recycling For information on ho...

Page 7: ...llation so any vehicle moving machinery construction machinery installed with the ME401 etc must not enter any facility where posted notices prohibit the use of wireless phones or two way radios Aircr...

Page 8: ...between the ME401 and any persons body Additional information on Specific Absorption Rates SAR can be found on the Cellular Telecommunications Internet Association CTIA Web site at www ctia org Batter...

Page 9: ...horized GSM network is available While a basic understanding of the different ME401 2 operational states is helpful configuring the ME401 2 unit does not require a highly skilled software programmer o...

Page 10: ...the unit make sure it is only mounted beneath plastic parts or similar parts wood but not beneath metal parts To reduce hum and noise in the FM radio it is recommended to place the unit at a minimum d...

Page 11: ...its overload and is also protected against over voltage For further information about connection possibilities of the digital output see chapters about installation later in this manual Motion sensor...

Page 12: ...ected to a ID06 Card reader Min 8V DC voltage at input 5 Pink Digital input 4 Can be connected to an external sensor for detecting a critical running mode or an alarm Min 8V DC voltage at input 6 Gree...

Page 13: ...ly through a 1 amp fuse 2 White Digital input 1 Connect to the operating hours counter Min 8V DC voltage at the input 3 Brown Digital input 2 Connect to the ignition signal Min 8V DC voltage at the in...

Page 14: ...interrupted by a red blink The unit is attached to the GSM network and the GPS is navigating Everything is OK No light The unit is not connected to a power supply Constant red light The unit is power...

Page 15: ...ngs garage would reduce signal quality MT SIGNAL MTC ACK SERIAL No SIGNAL GSM 22 SAT 8 SN 44 GSM is a measure for the quality of the GSM coverage The value should be at least 10 Maximum value for GSM...

Page 16: ...he unit is off thus no power on the unit Check if the installation is performed correctly according to the guidelines of this manual F3 The LED is constant red thus the unit is not attached to the GSM...

Page 17: ...supply voltage The current consumption of the relay must not exceed 200 mA DC current and the relay contacts must be specified to withstand the load that needs to be controlled NOTE The output can onl...

Page 18: ...UT1 ON With this command the output is activated permanently The output can be de activated again using the OFF command Deactivation of the output MT OUT1 OFF MTC ACK SERIAL No OUT1 OFF With this comm...

Page 19: ...problem and cannot find the information you need in the product documentation please contact M Tec A S M Tec A S Industrivej 10 9490 Pandrup Tel 45 99 73 00 20 Fax 45 96 73 74 07 E mail support m tec...

Page 20: ...product plus return freight costs will be issued not taken into consideration the original purchase costs Try to make the error description as detailed as possible Insufficient error descriptions will...

Page 21: ...installation Charging time for an empty backup battery 3 hours at 25 C Expected lifetime of the backup battery 3 years Digital inputs Up to 6 Digital outputs Up to 2 Temperature range In active runnin...

Page 22: ...tomotive Directive 2004 104 EEC UN regulative ECE R10 EMC rev 3 The ME401 product complies with the essential requirements of the Directive 2003 37 EEC and Directive 2006 42 EEC The ME401 product comp...

Page 23: ...for equipment on rolling stock CE The ME401 product complies with the essential requirements of the R TTE Directive 1999 5 EC as stated by the EC Declaration of Conformity Certificates and Declaration...

Reviews: