• Add liquid before restarting the mixer after sterilization to secure lubrication of the
bearings.
• Magnetic Particles
a
If presence of magnetic particles is suspected, remove the mixing head. Remove
the particles and reinstall the mixing head. (Refer to Male Bearing Installation,
Mixing Head Installation, and Drive Head Installation in this manual.)
b. Magnetic particles are not removed from the mixing head during CIP; they must
be removed manually or by alternative cleaning. Magnetic particles can cause
corrosion and damage. They can also cause a higher torque, which may cause
the mixing head to decouple and severely damage the vessel.
Other sterilization methods
For information on using other sterilization methods, please contact your local
representative for NovAseptic
®
GMP Mixer product information.
22 www.millipore.com