background image

 

  1. Components 

 
 
           
 
 
 
 
 
 
 
 
 
 
 
                                                   
 
 
 

 

 
 
 

            Stereo Microscope 

 

 

 
 
 
 
 
 
 
 
 
 
 
                                             
                                           
 

   

Stereo Microscope 

 

Adjustable WF10

×

eyepieces 

Focusing Assembly 

Binocular viewing head 

Zoom body 

Clamping Knob 

Objectives 

Glass stage 

Standard base 

Brightness adjusting knob 

Power cord 

Main Switch 

Coarse focusing knob 

Fine focusing knob 

Summary of Contents for PZ-4

Page 1: ...l is written for stereomicroscope To ensure the safety obtain optimum performance and to familiarize yourself fully with the use of this microscope it is recommended strongly that you study this manua...

Page 2: ...2 1 Components 4 2 Assembly 5 2 1 Assembly diagram 5 2 2 Detailed Assembly Procedure 6 3 Adjustment and Operation 9 3 1 Adjusting binocular head 9 3 2 Focus adjustment 10 4 Specification 11 5 Troubles...

Page 3: ...ottom side as this may result in electric shock 8 Use the factory supplied power cord please 2 Maintenance and Storage 1 All the lenses have been well checked and adjusted It is forbidden to disassemb...

Page 4: ...wer at once and wipe up the moisture 7 Do not disassemble any parts of the microscope which will affect the function or decline the performance of the microscope 8 Place the instrument in a cool dry p...

Page 5: ...tereo Microscope Adjustable WF10 eyepieces Focusing Assembly Binocular viewing head Zoom body Clamping Knob Objectives Glass stage Standard base Brightness adjusting knob Power cord Main Switch Coarse...

Page 6: ...bers indicate the order of assembly When assembling the microscope make sure that all parts are free of dust and dirt and avoid scratching any parts or touching glass surfaces Power cord Microscope ma...

Page 7: ...ewing head into the mounting port on the zoom body and tighten the viewing head clamping screw with provided hexagonal driver Note Working Environment Requirement 1 Ambient temperature 5 C to 40 C 41...

Page 8: ...e eyepiece as in Fig 5 When Not Wearing Eyeglasses Extend the folded eyeshades This makes observation easier by preventing the inverse incidence of light from between the eyepiece and your eyes 2 2 4C...

Page 9: ...depth The size of aperture iris diaphragm can be adjusted Switch the lever to left to open the aperture iris diaphragm to the right to close the aperture iris diaphragm Check the effect during observa...

Page 10: ...or 6 4 or 10 and turn the focusing knob to focus the specimen 4 Rotate the zoom body knob to the lowest magnification 0 8 looking only into the left eyepiece adjust the diopter ring on left eyepiece...

Page 11: ...knob to increase or decrease the focus knob tension 3 Brightness adjustment the right brightness adjustment knob is used to adjust the bottom illumination and the left brightness adjustment knob is us...

Page 12: ...Ratio 1 6 1 8 1 10 Objective Magnification 0 8 5 0 8 6 4 0 8 8 Eyepiece 24 10 WF Diopter adjustable Binocular Viewing Head Inclined at 20 interpupillary distance range 50 75mm Working Distance 78mm V...

Page 13: ...adjustment ring is too tight Loosen it properly 8 6 Zoom microscope body drops or specimen goes out of focus during observation Tension adjustment ring is too loose Tighten it properly 8 6 Outfit Comp...

Reviews: