MCF-LW06485 Operating Manual

 

Important safety information

 

Read this manual before attempting to install the device! Failure to observe recommendations included in this manual may be dangerous or cause a 

 

violation of the law. The manufacturer will not be held responsible for any loss or damage resulting from not following the instructions of this 

 

operating manual.

 

Do not dismantle or modify in any way. 

Avoid mechanical stress

 

Do not use any detergent or alcohol to clean the device.

 

Disposal information for users

 

Pursuant to and in accordance with Article 14 of the Directive 2012/19/EU of the European Parliament on waste electrical and electronic

   

equipment (WEEE), and pursuant to and in accordance with Article 20 of the Directive 2013/56/EU of the European Parliament on batteries and

  

accumulators and waste batteries.

 

The barred symbol of the rubbish bin shown on the equipment indicates that, at the end of its useful life, the product must be collected separately from  

other waste.

 

Please note that the lithium batteries must be removed from the equipment before it is given as waste and disposed separately. To remove the batteries refer to the  
specifications in the user manual. For additional information and how to carry out disposal, please contact the certified disposal service providers.

 

1. Description

 

This device can be interfaced to any Modbus RTU RS485 device to read and write any register of the connected device (up to 31 slaves or 512 bytes of data for 

 

every message) through the LoRaWAN® platform. Configuration is simply made using a configuration file uploaded to the interface via USB or with downlinks.

 

Summary of Contents for enginko MCF-LW06485

Page 1: ...EE and pursuant to and in accordance with Article 20 of the Directive 2013 56 EU of the European Parliament on batteries and accumulators and waste batteries Thebarred symbol of the rubbish bin shown...

Page 2: ...chargeable battery Class CLoRaWAN stack EU868 AS923 AU915 US915 ModbusRTU RS485 Integrated termination and polarization resistors USB On The Go IoTnode setup ad firmware upgrade via USB interface Powe...

Page 3: ...sitive power supply range 10 36Vdc J2 2GND Negative power supply Floor consumption included termination and polarization resistors 425mW Note add 600mW for aduration of 2 seconds for every LoRaWANtran...

Page 4: ...antenna connector in place as inthe picture 3 2 Configuration To deploy the sensor use LoRaWEB online tool to setup LoRaWAN credentials and other preferences only available for Windows iot mcf88 cloud...

Page 5: ...tart the update andwaiting for the end message 4 Setup 4 1Period Period isthe interval in minutes between one measure and the next one The sensor sends one measures for every transmission Value can be...

Page 6: ...ster Modbus address slave address expressed as decimal value Modbus function Function CodeRegister Type 1 2 3 4 5 6 15 16 Decaddress registerstarting address expressed as decimal value without offset...

Page 7: ...ding of one Modbus register and the one default 0 DST setto change DST default none Timesync uplink setto disable time synchronization request default enabled Normallysensor asks for atime sync at eve...

Page 8: ...graben 18 20 61273 Wehrheim 06081 5873860 Press Check to verify the correct communication betweet the LoRaWAN interface and the slave s 6 LoRaWAN network The sensor iscompliant with LoRaWAN specificat...

Page 9: ...ey AppSkey DevAddr The device exits factory activated with NONE mode On request devices can be shipped aleady activated Note in OTAAAppKey iswrite only in reading the field will always be empty even i...

Page 10: ...e ask to enginko This isvery useful especially in case of multiple devices configuration With Save button an XML file with the actual configuration of the sensor will be generated This isuseful to sto...

Page 11: ...ommands please refer to this document 11 Modbus overview 11 1 Modbus RTU basics ModbusRTU isbased on an RS485 bus TIA EIA 485 RS 485 isasingle differential balanced line half duplex Itprovides arobust...

Page 12: ...des odd parity no parity may also be used In order to ensure amaximum compatibility with other products itisrecommended to support also No parity mode The default parity mode must be even parity Remar...

Page 13: ...f the FCC Rules Operation issubject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that...

Page 14: ...m2m Germany GmbH Am Kappengraben 18 20 61273 Wehrheim 06081 5873860 E info enginko com PEC enginkosrl legalmail it W enginko com rev 1...