background image

 

 

 

               

 

 

15

  

 

 

 

UM200002 

ISSUE

 A 

REV

 00 

User Manual 

8

 

Appendix 

8.1

 

Power Supply 

 

Make: Meanwell 

 

Model: LRS-75-15 

 

Specification: 15V @ 5A 

8.2

 

Battery 

 

Make: Exide 

 

Model: EP 26-12 

 

Battery Type: Lead Acid Battery 

 

Capacity: 26AH 

 

Dimension: 180 x 125 x 175 cm 

 

Weight: 8.780KG 

8.3

 

Charge Controller 

Make: Generic 
12V/24V 10A Digital Charge Controller Module with 
Dual 5V USB & 12/24V DC Load Connection, with Solar & 
Mains Charging Feature. 

8.3.1

 

Features 

 

Build-In industrial microcontroller. 

 

Big LCD Display, All adjustable parameters. 

 

Fully 4 stage PWM charge management. 

 

Build-in  short  circuit  protection,  open-circuit 
protection,  reverse  protection,  over  load 
protection. 

 

Dual  MOSFET  reverse  current  protection,  low 
heat production. 

8.3.2

 

Specifications 

 

Rated Voltage: 12V / 24V 

 

Max. PV Voltage: 50V 

 

Max PV Input Power: 130W (12V) / 260V (24V) 

 

Dimension: 148mm x 78mm x 35mm 

8.3.3

 

System Connections 

 

Connect the battery to the charge regulator 

 

plus and minus 

 

Connect the photovoltaic module to the 
regulator 

 plus and minus. 

 

Connect the load to the regulator 

 plus and 

minus. 

8.3.4

 

Display Settings 

 

 

8.3.5

 

Mechanical 

 

8.3.6

 

Troubleshooting 

8.3.6.1

 

Charge icon not ON when sunny 

Power  Supply  not  connected  or  reversed.  Please 
reconnect. 

 

 

 

 

 

 

Or 15VDC 
Power Supply 

Summary of Contents for LogPRO TOUCH

Page 1: ...User Manual LogPRO TOUCH Touch based IoT Edge Gateway Data Logger Document Issue Rev Issue Date Prepared By Approved By UM200002 A 00 Aug 2020 MR PROP...

Page 2: ...mation in this document is subject to change without notice and should not be considered a commitment by M2MLogger M2MLogger assumes no responsibility for any errors that may appear in this document T...

Page 3: ...iring Plan for MODBUS RS 485 10 7 4 3 Wiring Plan for Analog Inputs 4 20mA 10 7 5 User interface 11 7 5 1 Home 11 7 5 2 Backup 12 7 5 3 Settings 12 7 5 4 Interval 12 7 5 5 Ethernet 12 7 5 6 GPRS 13 7...

Page 4: ...LOST PROFITS LOST SAVINGS OR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE ANY OF THE PRODUCTS EVEN IF M2MLOGGER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES O...

Page 5: ...w velocity in m s and A is cross section area in m2 For real world measurements it is important to understand that the velocity of the moving water varies both across the stream channel and from the s...

Page 6: ...6 UM200002 ISSUE A REV 00 User Manual 5 Components...

Page 7: ...7 UM200002 ISSUE A REV 00 User Manual 6 Cable Wiring Diagram LOGPRO TOUCH...

Page 8: ...ver The Air OTA upgrades LogPRO supports MODBUS RS 485 through screw terminals USB pen drive through USB type A connector 10 100 Mbps Ethernet through a standard Ethernet connector RJ 45 and GSM GPRS...

Page 9: ...9 UM200002 ISSUE A REV 00 User Manual 7 3 Mechanical Figure 3 Physical Dimensions mm...

Page 10: ...Shielded Ground 7 4 3 Wiring Plan for Analog Inputs 4 20mA Pin Function SP Switched Power Output SP0 SP3 AI Analog Input AI0 AI15 G Shielded Ground AC DC Line Voltage 24VDC GND LOGPRO Power Supply Fi...

Page 11: ...H HSDPA HSUPA TDSCDMA HSPA H HSPA 4G LTE LTE A TDD LTE FDD LTE airtel Carrier 14 4V Battery Voltage Battery Charging Status No Icon Functionality not supported Gray Battery not charging Green Battery...

Page 12: ...interval of device Option Description 1 min record every 1 minute 2 min record every 2 minutes 5 min record every 5 minutes 10 min record every 10 minutes 15 min record every 15 minutes 7 5 5 Etherne...

Page 13: ...sed to configure the APN for Internet access 7 5 6 2 Dialup This screen is used to configure the Dialup number for internet connection 7 5 7 FTP This window shows device FTP settings 7 5 7 1 URL This...

Page 14: ...d 0 82 3 62 0 89 add add 0 83 3 69 0 89 add add 0 84 3 76 0 89 add add 0 85 3 84 0 89 add add 0 86 3 92 0 89 add add 0 87 4 00 0 89 add add 0 88 4 07 0 89 add add 0 89 4 15 0 89 add map discharge conf...

Page 15: ...ully 4 stage PWM charge management Build in short circuit protection open circuit protection reverse protection over load protection Dual MOSFET reverse current protection low heat production 8 3 2 Sp...

Page 16: ...16 UM200002 ISSUE A REV 00 User Manual 8 4 Tripod Dimensions...

Page 17: ......

Page 18: ...1 B Friends Colony Industrial Area Shahdara Delhi 110095 India Telephone 91 11 22112232 WORKS B 8 First Floor FIE Patparganj Industrial Area Delhi 110092 India Telephone 91 11 22582090 email sales m2m...

Reviews: