4.1 Test Run – Simple Mode
To test the feeding process with the four sets of IR trigger sensors in the bill path.
4.1.1 Run – Value List
To check the gap adjustment by using the retrieved values.
1.
Choose a desired speed for testing.
2.
Change the solenoid to “Down” position.
3.
Start “Run – Value List
” by pressing the “
” after
selecting on the item.
4.
Place a bundle of 50
pcs
test notes
(Denomination: 1USD) on the hopper and pull the
hopper guide to fix the size of test note. The
machine starts running once it detects notes on
the hopper.
Note: The distance of two sides from hopper to banknote
shall be around 3mm to 5 mm.
5.
Once notes proceed, sensors retrieve value and
they are showed on the list.
•
MAX: Value of Tilt shall not over 4.
•
AVE: Value of Tilt shall not over 2.
•
QTY: Value of L shall not less than 10.
•
Value of IN Cnt and OUT Cnt shall be 50.
*Note: Repeat the same process FIVE times and the result
should be similar. If two or more test results are not under
acceptable range, please adjust the gap and test.