Service Manual – NC-6000 Date: OCT 1
st
, 2012 (Version 1.0)
Masterwork Automodules Tech. Corp., Ltd
Confidential
- 17 -
5.
Once notes proceed, sensors retrieve value and
they are showed on the list.
•
MAX: Value of Tilt shall not over 4.
•
AVE: Value of Tilt shall not over 2.
•
QTY: Value of L shall not less than 10.
•
Value of IN Cnt and OUT Cnt shall be 50.
*Note: Repeat the same process FIVE times and the result
should be similar. If two or more test results are not under
acceptable range, please adjust the gap and test.
4.2.2 Run – Wavform
To check the gap adjustment by using the graphic wave formed by the retrieved
value.
1.
Enter “Run – Wavform” by press the “
” after
selecting on the item.
2.
Place a bundle of 50
pcs test notes
(Denomination: 1USD) on the hopper and pull the
hopper guide to fix the size of test note. The
machine starts running once it detects notes on
the hopper.
3.
The wave shall be drowned around the white line
*Note: The information on Wave Form is for reference only,
please base on the information from VALUE LIST to test
and to adjust gap.
4.
Press the “Down” key to switch to next page and
see the wave form of distance.
*Note: The information on Wave Form is for reference only,
please base on the information from VALUE LIST to test
and to adjust gap.
4.2.3 Test Solenoid & Brake
To test the functionality of solenoid and brake by using 128 pairs IR array
(Manually start)