Service Manual – NC-6000 Date: OCT 1
st
, 2012 (Version 1.0)
Masterwork Automodules Tech. Corp., Ltd
Confidential
- 24 -
2. Once a IR sensor is covered, the curve on the
display reacts. Users may use hand or supporting
items to cover sensors and test the status of IR
sensors.
3. The following are the actions to get reaction from IR
sensors.
HPR: Cover the trigger.
P3-UpF: Reject pocket is full
S0-SpP: Check notes in reject pocket.
S1-SpD: Stacker is full.
IR0-IR2, IRs: Sensors in top bill path. When top
bill path is opened, there are reactions on the 4
channels.
IR4-IR5: Open the cover lid, there are reactions on
the 2 channels.
IRR: Cover the trigger sensor of jam in reject
pocket. (Refer to the pictures on the left side)
4.5.3 Burn In
To burn in the 128 set IR array.
[Factory used only]
.
1.
Highlight the option and press “
” to enter the
burn in mode.
2.
Press “
” to burn in IR array which will can keep
the sensor in a stable situation.
3.
Use “
F1
” and “
F2
” key to set the burn in time, and
press “
” to activate. IR array lights up while burn
in is under processing.
4.
Check the rollers and ensure each cog gears
smoothly.
5.
Press “
” to stop the burn in function and
press “
” again to go back to the upper layer.