t +31 88 500 2800
16
260123
10. ONDERHOUD
10.1 ONDERHOUD EN REINIGING
The lock has been factory lubricated for life and is maintenance free. The use of other lubricants is not permitted and will
void the warranty.
This lock contains electromechanical and electronic components that are subject to wear and tear depending on use and
on-site installation conditions. The manufacturer has no influence on these factors. As a result of this wear, the lock may
fail at the end of its normal service life.
Interval
Activity
As needed:
Using a dry cloth, polish the face plate and strike plate.
Note: Look for traces of dirt and wear (dust, escaping lubricant).
Periodically, depending on frequency of use (to be
determined by the operator):
Check for:
•
Tight fit
•
Smooth running
•
Noise during operation
•
Play of the latch
•
Contamination
•
Escaping lubricant
•
Moisture
If there are unusual noises, noticeable play, escaping lubricant or
similar; replace the lock.
10.2 EINDE LEVENSDUUR
The capacitors of the lock are required to provide the fail safe and fail secure operation when power is lost. If a capacitor
is compromised, it must be detected to ensure the failure operation can occur while the lock is still being supplied power
as it will no longer occur after power is lost.
The lock undergoes daily health checks on the capacitors. If a capacitor is found to be compromised the failure operation
will occur, based on the position of the failure mode switch. Once this occurs, the lock will no longer operate. This
operation will not work if the lock is wired using only two wires.
ELEKTRISCHE SLOTEN