Swim Spa
Problem
Noisy pump
and motor
No water flow
from jets
Water leakage
from under
swim spa
No air flow
from jets
Motor will
not operate
Black powder
film around
water line
Swim spa will
not shut off
Usual Cause
- Clogged or blocked suction or skimmer
- Low water level
- Damaged or worn motor bearings
- Pump not primed
- Adjustable jets turned off
- House circuit breaker tripped,
no power to system
- Faulty pump or motor
- Pump surges
- Slice valves closed
- Check unions & drain hoses
- Check for water seepage around jets
or at glued fitting
- Air control not open
- Jet nozzle not seated properly
- Jet nozzle missing
- House circuit breaker tripped or in
OFF position
- Improper or defective wiring or
electrical supply
- Pump thermal overload switch tripped
- Wearing in of turbo/blower brushes
- Swim spa is in heating cycle
- Swim spa is in filter cycle
- Swim spa is in Ready mode
Solution
- Clean suction grate and
skimmer basket
- Add water to normal water level
- Contact dealer
- See Priming section
- Turn on jets
- Reset circuit breaker at
house panel
- Contact dealer
- Check water level
- Open slice valves; ensure valve
safety clips are attached
- Close or tighten as necessary
- Contact dealer
- Open control
- Check jet nozzles
- Inspect jets and replace
as necessary
- Reset house circuit breaker in
panel box
- Contact dealer
- Auto reset after pump motor has
cooled. Contact dealer if pump
continues to cycle
- Will disappear after use
- Check ‘Set Temperature’ in
standard mode
- Normal. No need to change
- Check mode setting
Summary of Contents for DT6