MAAX SPAS PERFORMANCE SERIES
COMMON HARDWARE PROBLEMS
Problem
System not
operating
Heater not
operating
Water not clean
Abnormal
water usage
Overheating
Low water flow
from jets
No water flow
from jets
Noisy pump
and motor
Usual Cause
- House circuit breaker tripped or in
OFF position
- Water level too low - Heater mode
not selected - No power to heater
- Heater not operating
- Clogged or blocked floor suction of
skimmer - Filter clogged (dirty) - Poor
water chemistry - Insufficient filtering
time - Improper maintenance
- High content of solids in water
- Excessive evaporation and/or
splashing
- High ambient temperature
- Operating in FILTER mode-low speed
- Clogged or blocked suction or skim-
mer - Dirty filter - Jets in OFF position
- Slice valves closed
- Pump not primed - Adjustable jets
turned off - House circuit breaker
tripped, no power to system - Faulty
pump or motor - Pump surges - Slice
valves closed
- Clogged floor suction of skimmer
- Low water level - Damaged or worn
motor bearings
Solution
- Reset circuit breaker on house
breaker panel
- Add water to reach fill line on
Weir door - Refer to temperature/
heater functioning. See Control
instructions pg. 17 - Check house
circuit breaker - Contact dealer
- Clean floor suction/skimmer. Re
move blockage - Clean of replace
- See Maintenance section pg. 26
- Run filtration mode longer
- Contact dealer - See
Maintenance section, pg. 26 - Use
clarifier or drain and refill spa
- Use spa cover and refill as
necessary
- Contact dealer
- Select hi-speed jets - Clean floor
suction/skimmer. Remove block
age - Clean or replace - Open jets
- Contact your dealer
- See Priming section, pg. 15
- Turn on jets - Reset circuit
breaker at house panel - Contact
dealer - Low water. Check level
on Weir door - Contact your dealer
- Clean floor suction/skimmer
- Add water to normal water level
(15cm below lip) - Contact dealer