23
Owner’s Manual
E
nglish
1 touch = Low therapy jets
2 touches = High therapy jets
3 touches = Off
The low speed operation of Pump 1 is timed
to automatically turn off after two hours
of operation. The high speed operation of
Pump 1 is timed to automatically turn off
after 15 minutes of operation.
NOTE: With the standard configuration,
pump 1 will automatically operate in
low speed whenever the spa calls for a
filtration cycle or heat. When this automatic
activation occurs, the low speed of Pump
1 cannot be turned off; however, all other
control functions can be activated.
MODES OF OPERATION:
In the standard configuration your spa can be
switched among
Standard, Economy,
and
Sleep modes
by touching the ‘
TEMP’
pad and
then the ‘
LIGHT’
pad.
If your spa is in the
Standard mode
,
the low speed of Pump 1 and the heater
will come on automatically to maintain the
set temperature of the water. The pump
will circulate for approximately one minute
several times throughout the day to sample
water temperature. If your spa is set in:
Economy mode,
the heater will operate
ONLY
during the
filtration cycles. If your spa is set in the
Sleep mode,
the spa will heat to within 20°F (11°C) of the
set temperature only during filter cycles.
The pump will operate either during a normal
filtration cycle or, the heater and pump
will be activated when the heater housing
temperature drops below 45°F (7.2°C).
The selected mode will be displayed in the
LCD window of the control panel.
Temperature Controls
The maximum set temperature is 104°F (40°C)
and the minimum set temperature is 80°F
(26°C). The current water temperature or, if
the pump has not been running, two dashes,
will show on the display. If dashes are
displayed, you must first start the pump by
pressing the
PUMP 1
pad. Wait until the water
temperature is displayed (approximately 1
minute).
The set temperature of your spa may easily
be increased or decreased at any time using
the ‘
TEMP’
pad. Press the ‘
TEMP’
pad; the
set temperature will be displayed in the
LCD window. The next touch of ‘
TEMP’
will
change the set temperature either up or
down 1°F (0,5°C). If you want to increase
the temperature and the displayed indicates
the temperature was increased by 1°F (0,5°C),
continue to press the ‘
TEMP’
pad until the
desired set temperature is reached.
If you want to decrease the set temperature
and the LCD indicates that the temperature is
increasing,
STOP
. Wait a few seconds until the
actual temperature is displayed. Then press
the ‘
TEMP’
pad again. The set temperature
will be displayed. Press it again and the set
temperature will decrease by 1°F (0,5°C).
Continue pressing the ‘
TEMP’
pad until the
desired set temperature is reached.
If the spa is set in Standard mode or in a
filtration cycle, increasing the set temperature
may result in activating the heater. Decreasing
the set temperature will turn the heater off.
When the heater is operating, the LED below
the ‘
HEAT’
icon will be lit.
Pump 1
Touch the ‘
JETS’
pad to activate the primary
filtration pump. The sequence of the jet action is: