34
|
Manual de Servicio
Ingenieria de Servicio
DISASSEMBLY
Using a ¼” socket remove the screw that holds the Control
Board Harness ground, as well as the 2 black screws that
hold the Control Board Support to the Cabinet.
Slide the Card-Card Support Assembly to the left to
release the 2 tabs with which this assembly is attached to
the Cabinet.
Water Valve
With a screwdriver or ¼” socket, remove the screw that
holds the Valve at the top of the assembly..
Manually disconnect the Valve Harness
With Pliers remove the Clamp and the 2 straps from the
Valve Hose.
With a screwdriver or ¼” socket remove the 2 screws from
the Shower Valve. With Pliers remove the Shower Hose
Clamp.
Access Panel Back
With a screwdriver or ¼” socket, remove the 2 screws
holding the Access Panel Back, 1 on the right side, one on
the left side.