- 33 -
Dispenser Board
There is no self-diagnostic test for the dispenser board. The operation of the dispenser board is tested by
pressing each button and checking its proper operation.
Self-Test Sensor and Control System (0 7)
This test checks all five thermistors located through the unit. Once the test is started, the test code (0 7) will
stop flashing and the thermistor test results will appear on the freezer screen in the test order listed below.
The sequence number of the thermistor test will not be shown on the screen.
If the unit is not equipped with the Quick Cool option, the third thermistor (rapid cooling) will show 0 and three
audible beeps will sound on the temperature control panel. This is not a fault if the unit is not equipped with
the option of Fast Cooling.
Thermistor test results:
P =
Pass
0 =
Fail
S =
Short to 5 VDC
B =
Bad amplifier
The sequence of the thermistor test is:
1. Top cooler thermistor
2. Lower cooler thermistor
3. Quick cooling thermistor (0 displayed if the unit is not equipped with the Quick Cool option)
4. Evaporator thermistor.
5. Freezer thermistor.
Note:
The results of the thermistor test will appear in the sequence shown above. The number of the
thermistor test sequence will not be shown on the screen.
Summary of Contents for GSS21 Series
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ...The Condenser Fan Does Not Work ...
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 55: ... 53 Shock absorber Cooler thermistor Cooler lights Cooler light switch GEA00980 ...
Page 56: ... 54 GEA00977 Condenser fan Jelly Roll ...
Page 61: ......