P a g e
10
PRINTED : JAN’2015
REF NO. SM7715010-01-11
Part Name
Defrost Sensor
Operating Procedure
- Follow step 1-10 of replacing Fan Blade.
-
Follow step 1-2 of replacing Fan Motor.
1. Take out socket of Defrost sensor.
2. Cut out Cable Tie from Evaporator
tube.
3. Remove Al tape
.
4. Pull Defrost Sensor from Evaporator
tube.
5
.
After replacing Bimetal Thermo, reverse the steps above.