background image

 

25

 
 
 
 
 

PROBLEM FAILURE 

SOLUTION 

No power in the contacts. 

Check contacts. 

1 - The refrigerator does not 

cool (the compressor and the 

light bulb do not work). 

 

The wiring harness is disconnected or 

making a false contact. 

Connect pins or replace wiring harness. 

Potentiometer knob (temperature 

control) in 0 position. 

Adjust the knob to a position other than 0. 

The electronic board does not send a 

signal for the compressor to start 

operating. 

Check that the board is functioning 

correctly. 

Refrigerator in defrost cycle. 

Check the cycle and wait for it to end. 

Defective PTC. 

Replace PTC. 

Thermal protector with open circuit. 

Replace thermal protector. 

Wiring harness or connection with 

open circuit. 

Check current continuity of connections 

and wiring harness. 

2- The refrigerator does not 

cool (the compressor does not 

work, but the light bulb 

works). 

 

Compressor (burned or forced). 

Check compressor and replace if 

necessary. 

Leaking cooling unit. 

Search for and repair leak. 

Cooling unit with restriction. 

Search for and repair restriction. 

The compressor does not compress. 

Change the compressor. 

Temperature control knob in low 

position. 

Move knob to higher position. 

3 - The refrigerator does not 

cool (both the compressor and 

the light bulb work). 

 

The electronic board does not send a 

signal for the defrost cycle (the 

evaporator is blocked with ice). 

Check that the board is working correctly. 

Defrost resistance has an open circuit 

(evaporator blocked with ice). 

Change defrost resistance and melt ice. 

Defrost thermostat with open circuit 

(evaporator blocked with ice). 

Change defrost thermostat and melt ice. 

Short-circuit of defrost sensor (burned 

or blocked). 

Check or change wiring harness sensor. 

Defective fan engine 

Change fan engine. 

Cooling unit has a leak. 

Search for and repair leak. 

Magnetic seal does not seal. 

Repair or change magnetic seal. 

The door does not close well. 

Adjust door. 

Defective light bulb switch (light bulb 

on when door is closed). 

Connect or change switch or adjust door 

so that it switches light. 

4- The refrigerator does not 

cool enough (the light bulb 

works and the compressor 

works too much). 

 

 

 

Temperature control knob in high 

position. 

Adjust knob to a lower position. 

5- Refrigerator (freezes food 

in fresh food compartment), 

excessive compressor 

operation. 

Temperature sensor in the incorrect 

position. 

Check correct position of sensor. 

6- Excessive refrigerator 

operation. 

Temperature control knob in high 

position. 

Adjust knob to a lower number position. 

 

Summary of Contents for serviplus SEDNA ESTILO

Page 1: ...1 mabe SERVICE MANUAL FOR SEDNA ESTILO REFRIGERATORS from Mabe and G E PUB 06 MAN RE 02...

Page 2: ...2...

Page 3: ...AL DATA Electrical specifications No load operation Cooling unit Installation AIRFLOW Fan motors baffle lines ICE FACTORY Ice tray filling ice buckets ice disposal ELECTRONIC CONTROL BOARDS Deluxe ele...

Page 4: ...this technical manual is designed for technical personnel with knowledge and expertise in electricity electronics and mechanics as a guide for servicing these automatic no frost refrigerators Any pers...

Page 5: ...ment Follow these instructions 1 Start using your product keeping the factory preset positions medium level for both controls Let the appliance operate for 6 hours so that the temperature becomes stab...

Page 6: ...so see in the digital display an indicator light that swirls quickly This feature remains enabled for approximately an hour Once this period is over the refrigerator returns to normal operation Alarm...

Page 7: ...stem Forced Air Cooling Unit This kind of system uses fans in the freezer and the condenser area to remove the hot air from the condenser and the refrigerator area Natural Convection With Static Conde...

Page 8: ...ent consists of a bimetallic disc which when it detects an excessive temperature in the compressor or when its integrated resistance becomes too hot due to an excessive current bends and disconnects t...

Page 9: ...e its resistance when the temperature is higher The operating element of the PTC is basically a highly pure barium titanate disc with aluminum coating When a certain voltage is transmitted to the PTC...

Page 10: ...ID MID Control Position Room Temperature 70 F 90 F Fresh Food Compartment F Freezer F Compressor operation COOLING UNIT Refrigerant charge R134a 3 5 ounce 13 15 cubic foot models Compressor cooling ca...

Page 11: ...ts AC The evaporator fan motor circulate the warmer air of the fresh food compartment through the evaporator and sends cold air to the freezer and fresh food compartments The condenser fan motor works...

Page 12: ...the resistance is connected and to program the next defrost cycle DEFROST SENSOR The sensor s function is to detect the amount of ice and time that the resistance is enabled in order to vary the time...

Page 13: ...13 Evaporator fan motor Condenser fan motor assembly...

Page 14: ...CE UNPLUG IT FROM THE ELECTRICAL OUTLET C DISCONNECT THE WIRING HARNESS FROM THE FREEZER SENSOR CON1 D ENERGIZE THE APPLIANCE PLUG IT INTO THE ELECTRICAL OUTLET E AFTER APROX 4 SECONDS TURN ON THE COM...

Page 15: ...evaporator is low enough to have the Defrost Thermostat closed and allow current flow towards the Resistance F TO RE ENABLE THE COMPRESSOR OPERATION FOLLOW THE INSTRUCTIONS FROM STEP G G DE ENERGIZE...

Page 16: ...temperature control integrated to the board In case any of these components is damaged the whole assembly must be changed because each board is calibrated with these components When applying a 127 A C...

Page 17: ...200D2124G002 Main Board for 11 14 Models 220 V Polar Electronic with knob 200D2124G003 Main Board for 15 18 Models 110 V Polar Electronic with knob 200D2124G004 Main Board for 15 18 Models 220 V Polar...

Page 18: ...st points GND and P P which will turn off the compressor Three seconds later a signal will be sent to the defrost resistance to start working and at this moment the white and blue cables must give a r...

Page 19: ...TE THE VALUES BETWEEN EACH READING CAN VARY BECAUSE THE THERMOMETER SENSES TEMPERATURE FASTER THAN THE THERMISTOR SINCE THE THERMISTOR IS ENCAPSULATED IF THE THERMISTOR IS KEPT AT A CONSTANT TEMPERATU...

Page 20: ...t cycles will start after 48 hours of accumulated operating compressor time This feature is cleared by the board s integrated photocell when the fresh food compartment door is opened OPERATION TEST Se...

Page 21: ...sembly Airflow system Defrost system components are the thermostat the thermistor and the resistance heater Defrost drainage system The defrost duct is hidden behind the back and the insulating materi...

Page 22: ...22 DIAGRAM...

Page 23: ...23 LIGHT BLUE...

Page 24: ...PERES Compressor CBZN100L2 PARA SEDNA 13 Y 15 THE SAME FORM FOR POLAR 12 AND 14 IS 3 8 AMPERES OPERATING PRESSURES LOW SIDE AND HIGH SIDE De acuerdo al plano estos son los valores para el SEDNA Accord...

Page 25: ...ob to higher position 3 The refrigerator does not cool both the compressor and the light bulb work The electronic board does not send a signal for the defrost cycle the evaporator is blocked with ice...

Reviews: